INSTALLATION - DP1053MTK HUB MOUNTING (Wall, Ceiling,
Ground)
1.
For luminaires shipped with DP1053MTK hub kit, install provided hub mounts to
Luminaire hubs as shown in Figures D and E.
2.
Set hub mounts to the desired angle, and tighten the 1/4"-20 set screws on
each hub mount to 80 in-lbs (9.0 N-m).
3.
Install Luminaire using 5/16" screws or lag bolts.
!
WARNING - EXPLOSION HAZARD
When installed, the Luminaire may not be mounted outside the allowable range
shown in Figure A. Luminaire may only be mounted such that after install it is
oriented -90° to +45° from the 0° nominal shown in Figure A.
For Class II, Div. 1 and Simultaneous Presence Class I, Div. 2 and Class II
applications, the allowable mounting range is 0° to 45° only shown in Figure A.
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not guaranteed. In
accordance with Eaton's Crouse-Hinds Division's "Terms and Conditions of Sale," and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended
use and assumes all risk and liability whatsoever in connection therewith.