Replacing the system outer foil
1. Press the foil frame release buttons [D4]
and lift the outer foil section [B] upwards.
. Press the system outer foil release buttons
[B3] and pull down the system outer foil
[B2].
3. Insert the system outer foil [B2] until it
clicks as illustrated.
•
Always attach the system outer foil [B2]
in proper direction.
•
Always insert the system outer foil [B2]
to the foil frame [B1] when attaching to
the shaver.
Replacing the inner blades
1. Press the foil frame release buttons [D4]
and lift the outer foil section [B] upwards.
. Remove the inner blades [C] one at a time.
•
Do not touch the edges (metal parts) of
the inner blades [C] to prevent injury to
your hand.
3. Insert the inner blades [C] one at a time
until they click.
Troubleshooting
1
Trimmed hairs fly all over.
•
This can be improved by cleaning every time after shaving.
•
Clean the inner blades with the brush.
•
Apply oil (optional) after cleaning with water and leaving to
dry thoroughly.
System outer foil gets hot.
•
Apply oil (optional).
•
Replace the system outer foil if it is damaged or deformed.
2
3
Operating time is short even after charging.
•
When the number of operations per charge starts to
decrease, the battery is nearing the end of its life.
•
Apply oil (optional).
The odour is getting stronger.
•
This can be improved by cleaning every time after shaving.
You do not get as close a shave as before.
•
This can be improved by cleaning every time after shaving.
•
Replace the system outer foil and/or inner blades.
Expected life of
1
system outer foil and
inner blades.
•
Apply oil (optional).
Power switch cannot be turned OFF/ON.
•
Unlock the power switch.
2 3
Shaver stopped functioning.
•
Recommended ambient temperature for operation is
‑3°C. The shaver may stop functioning when out of
recommended ambient temperature range.
•
The battery has reached the end of its life.
System outer foil Approximately
1 year
Approximately
Inner blades
years
11