HTW ECO THERMAL PLUS Manual De Usuario/Instalador página 46

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6.3.2 Fast DHW
The FAST DHW function is used to force the system to
operate in DHW mode.
The heat pump and the booster heater or addition heater
will operate for DHW mode together, and the DHW
desired temperature will be changed to 60℃.
Go to MENU> DOMESTIC HOT WATER >FAST DHW.
Press "OK":
DOMESTIC HOT WATER(DHW)
DIS-
FAST
INFECT
DHW
CURRENT STATE
ON/OFF
ON/OFF
ON/OFF
DOMESTIC HOT WATER(DHW)
DIS-
FAST
INFECT
DHW
CURRENT STATE
ON/OFF
ON/OFF
Use "ON/OFF" key to select ON or "OFF".
INFORMATION
i
If CURRENT STATE is OFF, the FAST DHW is
invalid, and if CURRENT STATE is ON, the
FAST DHW function is effective.
The FAST DHW function is once effective.
6.3.3 TANK HEATER
The tank heater function is used to force the tank heater
to heat the water in tank. In the same situation, the
cooling or heating is required and the heat pump system
is operating for cooling or heating, however there still is
a demand for the hot water.
Also, even if the heat pump system fails, TANK HEATER
can be used to heat water in tank.
Go to ''MENU'' > ''DOMESTIC HOT WATER'' > ''TANK
HEATER''. Press ''OK''.
TANK
DHW
HEATER
PUMP
ON
ON/OFF
TANK
DHW
HEATER
PUMP
OFF
DOMESTIC HOT WATER(DHW)
DIS-
INFECT
CURRENT STATE
ON/OFF
ON/OFF
ON/OFF
DOMESTIC HOT WATER(DHW)
DIS-
INFECT
CURRENT STATE
ON/OFF
ON/OFF
Use ''ON/OFF'' to select ON or OFF. Use ''BACK'' to exit.
If TANK HEATER is effect, the following page will
appear:
If CURRENT STATE is OFF, TANK HEATER is
invalid.
If the T5(sensor of tank) is fault ,tank heater can't
work.
6.3.4 DHW Pump
The DHW PUMP function is used to return water of the
water net. Go to ''MENU'' > ''DOMESTIC HOT WATER''
> ''DHW PUMP''. Press ''OK''. The following page will
appear:
12
FAST
TANK
DHW
DHW
HEATER
PUMP
ON
ON/OFF
FAST
TANK
DHW
DHW
HEATER
PUMP
OFF
INFORMATION
i
Tabla de contenido
loading

Tabla de contenido