intercom call from apartment station to special decoder
—
sending of pedestrian door lock release command from switchboard
—
sending of driveway door lock release command from switchboard
—
sending of special code from call station or switchboard
—
Call from calling station to a user in the system (function available with FW release 4.0 or higher)
Alternatively to the above described operation mode, the special decoder can be used to send the alarm
indication to the concierge switchboard by pressing the remote button (PC). In this case, the dip-switch 1
must be in ON position.
EVENTS PROGRAMMING IN STANDARD OPERATING MODE (DIP
1 = OFF)
1 to 4 events can be programmed, if the competence areas jumper is in C or Q position, or up to 32 events
if the jumper is in S position: the events will activate the special decoder relay, according to configuration.
1 – Set the competence areas jumper to the desired position.
2 – Set CODE dip-switch as indicated in the system manual, if the event needs this setting (only for intercom
call coming from a door unit).
3 – Press the programming button and release it when the led turns on.
When entering in programming mode, stored events will be overwritten. Before accessing
programming mode, it is suggested to restore factory settings and program events in a single
session.
4 – Generate the first event that the special decoder must acquire (for example, press the door lock release
button of a system apartment station).
5 – The led blinks once to indicate that the first event has been programmed. The led stays on to indicate
that the special decoder is still in programming phase.
6 – Generate the other events which the special decoder must acquire. For each event the led will blink for
the same number of times as the events programmed: 2 times for the second event, 3 for the third.
After the last available event has been programmed, the led will turn off to indicate exit form programming
mode.
When SCQ jumper is in S position, the led will blink only once, without indicating the programmed
event number.
7 – Exit from programming mode by following one of these two procedures:
–
Press the programming button
–
Generate the same event several times
–
Wait until programming time is elapsed
However, exit from programming mode is indicated by the led, which turns off.
In case of no events reception for a time greater than 5 minutes, the special decoder automatically
quits the programming mode and turns the led off (the events already acquired stay stored).
Programming details and behaviour of the special decoder for each single programmable event are
described below.
EVENT: PEDESTRIAN DOOR LOCK RELEASE BUTTON FROM APARTMENT
STATION
Program the event by pressing the pedestrian door lock release button of an apartment station, which must
activate the special decoder relay (see paragraph about events programming).
Assume that this apartment station is in the column number "Column ID" and has user code "CODE".
When the programming procedure has been performed, the relay is activated according to the position of
the jumper SCQ:
•
Position Q: the pedestrian door lock release button of any system user activates the decoder.
•
Position C: the pedestrian door lock release button of any user of the column "Column ID" activates
the decoder.
•
Position S: the pedestrian door lock release button of all apartment stations (also those in parallel) of
1
DS1083-019D