Only for fluids of group 1:
Danger of explosion!
Do not smoke or use open flames when
working with flammable / explosive fluids.

Appropriate use

The equipment may only be used for its
intended purpose. The equipment has been
built exclusively for:
q Fluids of group 1 (except unstable gases
such as acetylene) and group 2 as per
Pressure Equipment Directive 97/23/EC,
for which the operating parameters are
mentioned on page 18 (Technical Data).
q To separate out microbiological organisms
and produce sterile compressed air.
q For the filtration of saturated steam.
Any use or one beyond those listed above
shall be considered inappropriate. We shall
have no liability whatsoever for any damage
incurred as a result.
Notes on starting up
PICTURES 1 - 10 (single), page 16
PICTURES 1 - 10 (multiple), page 17
Before initial commissioning
The filter elements do not come installed in
q
the filter housing.
All the threaded connections of the pres-
q
sure vessel must be tightened to the max
torque value.
DE
GB
FR
Achtung!
Achtung!
Gefahrstoffverordnung
LT
LV
PL
Hochentzündliches Fluid
beachten!
Achtung!
Achtung!
Hochentzündliches Fluid
Explosionsgefährliches Fluid
Achtung!
Explosionsgefährliches Fluid
NL
IT
ES
SI
SK
RO
Visually inspect the housing for any external
q
damage.
Check the housing for leaks.
q
Initial commissioning
Slowly apply pressure to the system by first
q
opening the upstream valve (9).
Information concerning
maintenance
PICTURES 11 - 16 (single), page 16
PICTURES 11 - 17 (multiple), page 17
Before starting any maintenance work,
q
ensure that the pressure vessel has been
depressurized and has cooled down, and
cannot be put back into operation during
the maintenance work.
The filter elements must be changed at
q
regular intervals. At the latest, once the
permissible differential pressure has been
reached.
The following recommendations apply:
Annual maintenance
q Damaged components should be replaced
by new ones. If damage is found, the entire
vessel is to be replaced.
q The pressure vessel has been designed
for a life of 10 years.
q The housing seal should be changed when
servicing the filter element (14).
q Check for leaks once the maintenance
work is complete!