Problem
Possible cause / Action
White film
Hard water minerals: clean the interi-
on inside
or by using a damp sponge with
surface
dishwasher detergent. Wear rubber
gloves.
Unsatisfac-
∙ Improper loading ∙ dishes are re-
tory drying
moved too soon ∙ wrong program has
result
been selected ∙ use of cutlery with a
low-quality coating
Error codes
For some malfunctions, the control lamps will show
the following error to warn you:
Control lamps
Meaning / Possible cause
flashes
Water inlet fault! Faucet not open,
inlet blocked or water pressure too
low.
Malfunction of heating element.
ECO
Overflow / water leakage!
ECO
Failure of communication between
main PCB with display PCB.
CAUTION:
 If overflow occurs, turn off the main water supply
before calling an authorized technician.
 If there is water in the lower housing part due to
an overfilling or a small leak, remove this water
before restarting the appliance.
NOTE:
If a problem persists after following the steps above,
please contact your distributor or an authorized tech-
nician.

Technical Data

Electrical connection / Water supply....................
Connection voltage: ...............220-240 V~ / 50 Hz
Connection power: .....................1.170 – 1.380 W
Water pressure: .............................0.04 – 1 Mpa
Dimension H x W x D / Weight...........................
Unit size: ..........................43.8 x 55.0 x 50.0 cm
Net weight: .......................................ca. 19.0 kg
Available accessory.........................................
Inlet hose safety system: ..........Art.-No. 8900 410
For more information about the product, scan the QR
code on the supplied energy label and/or visit the
official website of the product data bank:
https://eprel.ec.europa.eu
The right to make technical and design modifications
during continuous product development remains
reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.
67
Tabla de contenido
loading

Tabla de contenido