Initial Operation - Flex VAC 800-EC Instrucciones De Funcionamiento Originales

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
VAC 800-EC
Installing and replacing exhaust
hood
Exhaust hood for mixing work
Press pre-filter fabric G3 in exhaust hood
for mixing work (1.).
Push exhaust hood for mixing work under
the rail (2.) and lower it to lock it (3.).

Initial operation

Insert the mains plug into the socket.
Turn control knob to the required power
(0-100%).
The fan motor only starts after approx.
5-10 s (electronic self-test program runs
first)
– Control diode turns green:
air flow sufficient and therefore filter OK
– Control diode turns red:
air flow too low, change filters.
Operating instructions
When working with renovation machines
separate safety exhaust systems are
required to exhaust the high volume of dust
directly into the machine. The remaining fine
dust in the room air is extracted and filtered
out by the air purifier. This prevents dust
from entering other areas.
The continuing collection of dust clogs the
filters more and more over time and the air
flow rate is continuously reduced until the red
warning light comes on. At this point the filters
must be replaced.
The product is fitted with a LED display
(green/red), which warns of a blocked filter.
– When the LED turns red, the G3 and G4
filters or F7 must be replaced.
– If the warning light shows red again
immediately after replacing the filters, the
H13 filter must also be replaced.
Work area
19
Tabla de contenido
loading

Tabla de contenido