Technical Specifications - Flex VAC 800-EC Instrucciones De Funcionamiento Originales

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
VAC 800-EC
Do not operate in the vicinity of sources
of open flame, such as combustion
heater, furnaces etc. to prevent suction
of toxic carbon monoxide.
Inspect the product before use for the
first time to ensure that the case, seals
and power cord are in good condition.
It must not be damaged.
A bent frame or defective seals may
result in hazardous dust exposure.
Never operate the product with a damaged
power cord.
The cord must be inspected regularly
and replaced with a new cord if
necessary.
Faulty products must be sent for repair
immediately.
The product is intended for operation
indoors only and must not be exposed to
moisture and must not be placed in
puddles or standing water.
If the product accidentally becomes wet,
pull out the power plug and leave the
product to dry thoroughly before using
it again.

Technical specifications

Machine type
Dimensions (WxHxD)
Weight
– with filters (G3 + G4 + H13)
– without filters
Air volume
– with new filters (G3 + G4 + H13)
– with MAX setting and green light
– with dirty filters and red warning light
Dirt-holding capacity of filters
Fan motor
Power
Power consumption
Mains voltage
Speed range of fan
Make sure that the product is secure
during transport.
While the product is operating do not
place any objects such as clothing on it.
The air vents must be kept clear if hoses
are not connected.
Make sure that clean filters in good
condition are used. Blocked filters may
cause an overload of the motor. Use only
recommended filters in accordance with
the specifications for the site.
The product must be disconnected from
the power supply for maintenance,
repairs and cleaning.
Gloves and mask must be worn when
handling dirty filters.
Pack used filters in closed bags for
disposal.
Use only filters specified for this product.
When cleaning the air purifier do not use
a water jet or compressed air but only dry
vacuum and wipe it with a moist cloth.
Allow the product to dry before installing
new filters.
mm
kg
3
m
/h
Pa
kW
A
V AC
Hz
rpm
approx. 0 - 3,930
VAC 800-EC
Air purifier
390x508x373
11.0
7.2
approx. 544
400 - 544
400
approx. 320
0,17
1.7 - 1.45
230
50/60
15
Tabla de contenido