Protection Fuse; Dimension And Weight; Description Wiring Diagram; Trouble Maintenance - Mase Generators IS 2500 Manual Uso Y Mantenimento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
GENERATORS
Code E - 85
This code indicates that the unit has
stopped because the voltage has dropped to below 70%
of the nominal value for longer than 15 seconds.
Code E - 87
This code indicates that the unit has
stopped because the generator voltage has not reached
80% of the nominal value 30 seconds after starting. This
could be caused by insufficient motor RPM or a broken
alternator.
batt
This code indicates that the battery
is low. When this code appears, the generator is not
stopped.
WARNING
When a circuit breaker has tripped with a consequent
generator stop, the panel must be reset by pressing the
"OFF" button in order to restart the unit.
INFORMATION
If the unit is started and the alternator does not produce
voltage, or the control panel does not read voltage, the
latter switches off completely after one minute, stopping
the unit.
8 PROTECTION FUSE ( fig. 4 )
1) RELAY CIRCUIT FUSE
2) BATTERY CHARGER FUSE
9 DIMENSIONS AND WEIGHT( fig. 7 )
IS 2500
a) Lenght
mm.580
b) Width
mm.430
c) Height
mm.430
Weight
Kg. 80
10 DESCRIPTION WIRING DIAGRAM (fig. 8 )
1
ROTOR
2
STATOR
3
DIODE 3A
4
VARISTOR
5
PRINTED CIRCUIT RELAY
6
POWER TERMINAL BOARD
7
RELAY CIRCUIT TERMINAL BOARD
8
CONTROL PANEL TERMINAL BOARD
9
FUSE 1A
10
CAPACITOR
11
BATTERY CHARGER REGULATOR
12
FUSE
13
STARTER
14
BATTERY
15
FUEL PUMP
16
FUEL SOLENOID
17
OIL PRESSURE SWITCH
18
OVERHEAD ENGINE THERMOSTAT
19
WATER TERMOSTAT
20
ALTERNATOR THERMOSTAT
GB
IS 3500 IS 4500/5500
mm.660
mm.720
mm.460
mm.490
mm.545
mm.565
Kg
94
kg 110
22
IS 2500 - 3500 - 4500 - 5500

11 TROUBLE MAINTENANCE

12 TROUBLE SHOOTING

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Is 3500Is 4500Is 5500