3.­ Slide­the­large­washer,­then­wheel­onto­the­axle­next­to­the­
cotter­pin.
4.­ Slide­the­spacer­onto­the­axle­next­to­the­wheel.
5.­ Slide­the­partially­assembled­axle­through­the­wheel­support­
frame.
6.­ Slide­the­spacer­onto­the­axle­next­to­the­wheel­support.
7.­
Slide­the­wheel­then­large­washer­onto­the­axle­and­hold­in­
place­with­the­remaining­cotter­pin.
8.­ Install­the­caps­over­the­larger­washers­to­finish­the­wheel­
assembly.
PREPARING FOR OPERATION
1.­ Check­the­heater­for­possible­shipping­damage.­If­any­is­
found,­immediately­contact­the­manufacturer­at­
800-251-0001.
2.­ Follow­all­of­the­"Precautions".­
3.­ Fill­the­fuel­tank­with­clean­kerosene.­In­extremely­cold­
weather,­condensation­may­develop­in­the­tank­and­it­is­
recommended­that­a­tablespoon­of­de-icer­be­added­for­
each­gallon­(4­liters)­of­fuel­in­the­tank.­When­filling­the­
heater,­use­at­least­2­gallons­(8­liters)­of­fuel.­Be­sure­heater­
is­level­and­do­not­overfill.­Use­a­funnel­or­can­with­a­long­
fill­spout.
IMPOrTanT: Before filling fuel tank the first time or after ex-
tended storage periods, drain the fuel tank of any moisture
or condensation.
4.­ Locate­heater­at­a­safe­distance­from­combustible­materials.­
Models­MH50KR­&­MH75KTR­are­not­suitable­for­use­on­
wood­floors­or­other­combustible­materials.­When­used,­the­
heater­should­rest­on­suitable­insulating­material­at­least­1­
inch­thick­and­extending­3­ft.­or­more­beyond­the­heater­in­
all­directions.
HEATER START up
1.­ MH50Kr:­Plug­the­heater­into­a­grounded­115V,­60­Hz,­1­Ø­
outlet.
MH75KTr, MH125KTr, MH175KTr & MH210KTr: Turn­
thermostat­to­lowest­setting,­make­sure­"On/Off"­switch­
is­"Off".­Plug­the­heater­into­a­grounded­1 15V,­60­Hz,­1­Ø­
outlet.­Turn­thermostat­to­highest­setting.­Start­heater­by­
pushing­toggle­switch­to­"On"­position­(light­signifies­switch­
is­in­"ON"­position).­Adjust­thermostat­to­desired­setting.­
Heater­will­cycle­on/off­as­heat­is­required.
EXTENSION­CORD­REQUIREMENTS:­Up­to­100'­(30.5m)­use­
16­awg.­conductor.­101'­-­200'­(30.5­-­61.0m)­use­14­awg.­
conductor.
For all models:
•­ In­cold­weather­(below­10°­F),­starting­may­be­improved­by­
holding­a­finger­over­the­vent­hole­of­the­pump­adjustment­
screw­cap­until­the­heater­starts.­
•­ This­unit­is­equipped­with­an­interrupt­circuit.­The­reset­is­
integrated­into­the­"On/Off"­switch.­If­the­unit­does­not­
start,­toggle­the­switch­to­"Off",­wait­5­min.­and­toggle­
the­switch­to­"On".
HEATER SHuT DOWN
1.­ MH50Kr: Unplug­heater­from­power­source.
MH75KTr, MH125KTr, MH175KTr & MH210KTr: Push­
"On/Off"­switch­to­"Off"­position.­For­extended­shutdown,­
unplug­heater­from­power­source.
resTarT aFTer saFeTY sHuTdOwn­(MH50Kr, MH75KTr,
MH125KTr, MH175KTr & MH210KTr) see page 7
Mr. Heater, Inc. | Kerosene Forced Air Heater
MH50KR­-­Unplug­unit.­Wait­5­minutes.­Plug­back­in.
MH75KTR,­MH125KTR,­MH175KTR­&­MH210KTR­-­Toggle­switch­to­
"OFF"­position,­wait­5­minutes.­Restart.

MAINTENANCE AND STORAGE

WARNING.­To­prevent­personal­injury,­unplug­the­heater­from­the­
wall­outlet­before­servicing.­
For­maximum­efficiency­and­trouble-free­service,­make­the­
following­periodic­maintenance,­cleaning­and­inspections.
AdjUSTING PUMP PRESSURE
Due­to­varying­fuel­viscosities­and­normal­component­wear­the­
pump­pressure­on­this­heater­may­need­to­be­adjusted.­­
ADJUSTMENT­PROCEDURE:
1.­ Fill­fuel­tank.
2.­ Start­heater.
3.­ Locate­the­fuel­pressure­adjustment­screw­(ref.­#29)­in­the­
exploded­parts­drawing.­­The­pressure­adjustment­screw­
is­located­at­the­rear­of­the­heater,­in­the­air­filter­housing­
cover­(approx.2"­from­the­left­side­and­1"­from­the­top).­
Remove­and­discard­the­rubber­cap­(ref.­#4)­to­expose­the­
screw.
4.­ Using­a­flat­bladed­screw­driver,­turn­the­pump­pressure­
adjustment­screw­clockwise­to­increase­pump­pressure­and/
or­counter-clockwise­to­decrease­pump­pressure.­­Base­pump­
pressures­can­be­found­in­the­specifications­chart­on­page­3­
of­the­"Operating­Instructions­and­Owners'­Manual".
5.­ For­best­results,­the­nose­cone­in­the­combustion­chamber­
should­be­cherry­red­with­no­dark­spots­and­the­flame­
should­not­extend­beyond­the­nose­cone.
IMPROPER­PRESSURE­ADJUSTMENT
problem: ­­ Heater­does­not­have­a­strong­consistent­flame.
­
­
Heater­smokes­and­spits­raw­fuel.
­
­
Nose­cone­does­not­get­cherry­red.
Adjustment:­Pump­pressure­is­too­low.­­
­
­
Turn­adjustment­screw­clockwise­to­increase­pump­­
­
­
pressure.
problem:­
Flame­extends­beyond­the­end­of­the­heater.
Adjustment:­Pump­pressure­is­too­high.­
­
­
Turn­adjustment­screw­counter­clockwise­to­­
­
­
decrease­pump­pressure.
DAILY SCHEDULE
1.­ GENERAL.­Make­general­visual­inspection­of­heater­for­loose­
or­damaged­parts.­Check­nuts­and­bolts­to­insure­against­
looseness­caused­by­vibration­or­rough­handling.­Damaged­
parts­should­be­repaired­or­replaced­before­using­heater­
again.­Check­heater­operation­to­be­sure­it­is­operating­
normally­(See­"Servicing"­section­for­description­of­normal­
operation).
2.­ FILTERS.­Dirty­air­or­fuel­filters­will­cause­an­imbalance­in­
the­air-fuel­mixture.­The­best­indication­that­this­condition­
exists­is­an­increase­in­odors­or­difficulty­getting­your­heater­
to­ignite.­This­heater­should­never­be­operated­without­the­
filters­in­place.­If­required,­clean­filters­as­described­under­