Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

SPECIFICATIONS
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)
Model
50KR
Burn Rate:
50,000 Btu/hr (14.7 kW)
Fuel Rate:
0.37 gal/hr (1.4 L/hr)
Electrical Input:
115V, 60Hz, 3.5a
Line Protection:
10 amps
Min. Operating Voltage:
110V
Pressure Setting:
3.5 psig (24 kPa)
Max. Outlet Temperature: 1450
F (787
o
Fuel Tank Capacity:
4 gallons (15.1 L)
Ignition:
Direct Spark, Continuous Direct Spark, Continuous
Spark Generator:
Igniter 13 kV, 10ma
Primary Safety Control:
Solid State Control
OPERATING PRECAUTIONS
SAFETY PRECAUTIONS
75KTR
75,000 Btu/hr (22 kW)
0.55 gal/hr (2.1 L/hr)
115V, 60Hz, 4a
10 amps
110V
4.2 psig (29 kPa)
C)
1450
F (787
C)
o
o
o
6 gallons (22.7 L)
Igniter 13 kV, 10ma
Solid State Control
Mr. Heater, Inc.| Kerosene Forced Air Heater
125KTR
175KTR
125,000 Btu/hr (37 kW)
175,000 Btu/hr (51 kW)
0.96 gal./hr (3.5 L/hr)
1.3 gal/hr (5.0 L/hr)
115V, 60Hz, 5.5a
115V, 60Hz, 5.5a
20 amps
20 amps
110V
110V
5.1 psig (38 kPa)
6.8 psig (40 kPa)
1450
F (787
C)
1450
F (787
o
o
o
8.45 gallons (32 L)
13.5 gallons (51 L)
Direct Spark, Continuous
Direct Spark, Continuous
Igniter 13 kV, 10ma
Igniter 13 kV, 10ma
Solid State Control
Solid State Control
OPERATING INSTRUCTIONS
UNPACKING
ASSEMBLY
3
210KTR
210,000 Btu/hr (61.5 kW)
1.6 gal/hr (6.0 L/hr)
115V, 60Hz, 5.5a
20 amps
110V
8.2 psig (58.6 kPa)
C)
1450
F (787
C)
o
o
o
13.5 gallons (51 L)
Direct Spark, Continuous
Igniter 13 kV, 10ma
Solid State Control
Tabla de contenido
loading

Resumen de contenidos para Mr. Heater 50KR

  • Página 7: Especificaciones

    Encendedor 13 kV, 10 ma Encendedor 13 kV, 10 ma Control de seguridad Control en el estado Control en el estado Control en el estado Control en el estado Control en el estado primario: PRECAUCIONES DE UTILIZACIÓN PRECAUCIONES DE SEGURIDAD Mr. Heater, Inc.| Kerosene Forced Air Heater...
  • Página 8: Desempacado

    IMPORTANTE: antes de llenar el tanque de combustible la primera vez o después de períodos de almacenamiento extendidos, drene el tanque de combustible para retirar la humedad y la condensación. ENCENDIDO DEL CALENTADOR MH50KR: MH75KTR, MH125KTR, MH175KTR y MH210KTR: Mr. Heater, Inc. | Kerosene Forced Air Heater...

Tabla de contenido