Parameter menu
Pressure gauge threshold
This function can be used to define the mainte-
nance interval of the desoldering tool. This is done
by setting the value in mbar at which the electric
pressure gauge issues a warning signal when the
intake system is contaminated (LED of the vacuum
pump switches from green to red). The set value is
dependent on the suction nozzles used.
Adjustable
-400 mbar to -800 mbar
factory setting
-600 mbar
1. The system (tips and filter) must be free.
Interface COM 1 / 2
Option
Description
RS232
Serial communication with PC or other compatible Weller devices (factory setting).
Air
The COM 1 port is configured as a foot switch input for activating the air flow.
Vac
The COM 1 port is configured as a foot switch input for activating the vacuum.
PickUp
The COM 1 port is configured as a foot switch input for activating the PickUp vacuum.
Stop&Go
The COM 1 port is used to drive an optional optotransmitter so that a KHE-P control
unit can be activated via an optical fibre.
The output is activated when a tool is used. In addition, the floating switched output is
closed. The output is off in the Standby, Auto Off or Off positions, or if no tool is inserted.
Floating switching output 1
Floating switching output 1 is located at the COM 1 port.
Option
Description
OFF
(factory setting)
ZeroSmog
The floating switching output is closed when a tool is in use. Selected Zero Smog
extraction systems can be connected using an optional adaptor (WX HUB). The rear
RS 232 port remains functional.
Switching output is open in the Standby, Auto Off or Off positions, or if no tool is inser-
ted.
42
2. Select the menu item „Pressure gauge
threshold" in the menu.
3. Set the „Pressure gauge threshold" pressure
value with the UP or DOWN button. The status
LED switches back and forth between red and
green. Use the UP button to increase vacuum
by 50 to 80 mbar, then pinch the vacuum tube
and check whether the LED switches from
green to red.
4. Adopting the set change.
Notice
If the COM 1 port is also configured for „Stop&Go" use, the „Filter full"
message is evaluated by the WX HUB and, where applicable, a
message appears on the display .