Weller WXR 3 Traducción Del Manual Original página 22

Ocultar thumbs Ver también para WXR 3:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Parameter menu
Standby Temp.
The soldering tools have a usage detection device
(sensor) in the handle which automatically initiates
cooling to Standby temperature when the solde-
ring tool is not in use.
Standby time (temperature deactivation)
When the soldering tool is not in use, the tem-
perature is reduced to Standby temperature on
expiration of the set Standby time. The display
reads „Standby".
Press control key to exit Standby mode. The
sensor integrated tool detects the change in state
and deactivates Standby mode as soon as the tool
is moved.
AUTO OFF time (automatic switch-off time)
When the soldering tool is not in use, the soldering
tool heater is switched off when the AUTO OFF
time expires.
Temperature deactivation is performed indepen-
dently of the set standby function. The actual
temperature is indicated and serves as a residual
heat display. The display reads „AUTO OFF".
Sensitivity
Option
Description
low
Non-sensitive – Reacts to heavy (long) movement
normal
standard (factory setting)
high
Sensitive - Reacts to light (short) movement
---
The tool is not supported
Max. hot air duration WXHAP
The on-time of the hot air flow of the WXHAP can
be limited in increments of 1 to between 0 and 300
sec. The factory default is 0 s („OFF"), i.e. air flows
only as long as the button on the hot air tool or the
optional footswitch is pressed.
Offset (Temperature-Offset)
The actual soldering-tip temperature can be
adapted by entering a temperature offset around ±
40 °C (± 72 °F).
Menu access
Menu access
Option
Description
OFF
standby time is deactivated (factory
setting)
1-999 min standby time, individually adjustable
---
The tool is not supported
Menu access
Option
Description
OFF
AUTO OFF function is deactivated
(factory setting)
1-999 min AUTO-OFF time, can be set indivi-
dually.
Menu access
Menu access
Option
Description
OFF
No duration defined
(factory setting)
1-300 s
Individually adjustable
Menu access
Tool parameters
Tool parameters
Tool parameters
Tool parameters
Tool parameters
Tool parameters
39
Tabla de contenido
loading

Tabla de contenido