3. Technical data

General
Digital oil pressure gauge with actual and maximum display
Bar graph display 33 segments (with peak and hold function)
4
/
digit LC display (15 mm) with back light illumination
1
2
Start up check:
LCD Segment check, maximum pressure & current displayed units
(MPa or psi), Auto power off status, Serial number with software version
Pressure range, accuracy and resolution
Pressure range
Accuracy
Display resolution
Weight and dimensions
Weight
Dimensions Ø x d x h
Operating and storage conditions
Operating temperature
Fluid temperature
Storage temperature
Rel. humidity
Environmental operating limits
Protection
Vibration
Shock
Reliability Cycles
Battery type and life time (typical)
Type
Life time
SKF THGD 100
0 - 100 MPa (14 500 psi)
± 0,1% FS max.
0,01 MPa / 1 psi
540 g (19 oz)
79 x 33 x 118 mm (3 x 1.3 x 4.6 in)
(Without rubber protection sleeve)
0 / 50 °C
-20 / 80 °C
-20 / 60 °C
< 85%
IP 67 (EN 60529)
10 500 Hz / 5 g (IEC 60068-2-6)
25 g / 11 ms (IEC 60068-2-29)
100 million
2 x LR6 (AA) alkaline batteries
1500 hours, (100 hours with back light function)