Fig. E
25
17
Pairing the Dust Extractor with a Tool using
Wireless Tool Control™ Mode (Fig. A, D)
CAUTION: When the dust extractor is being controlled
with the remote or paired power tool it may start or
stop without warning.
WARNING: Do not attach the remote strap to
moving parts.
To Pair with a D
WALT Remote or
e
Wireless Tool Control™ Tool
1. Press the three position switch
Control™ ( ) position.
2. Press and hold the Wireless Tool Control™ pairing
button
11
on the DCV585 and pull the trigger on
the Wireless Tool Control™ equipped tool or press the
button on the remote
14
3. The LED
will be steadily illuminated to indicate a
19
successful pairing.
nOTE: Only one transmitter can be paired to the
DCV585 at a time. If the unit is already paired the
previous transmitter will be overridden.
To Unpair with a Wireless Tool Control Tool™ or
Remote
•
Press and hold the Wireless Tool Control™ pairing
button
11
on the DCV585 and pull the trigger on
the Wireless Tool Control™ equipped tool or press the
button on the remote at the same time.
•
The LED
19
will flash slowly to indicate a
successful unpairing.
REMOTE SPECIFICATIONS
Voltage
V
DC
Battery life
Signal Range
FCC ID
IC
Weight
26
17
to the Wireless Tool
3
at the same time.
3
3 Years
<30' (10 m)
YJ7DCV585
90829-DCV585
0.60 oz (0.017 kg)
Dust Extractor Cleaning
To Empty Tank (Fig. A, F–H)
The sound of the motor changes and suction is reduced
when the tank is full.
1. Press the three position switch
and remove the battery.
nOTE: Wait an adequate amount of time after shutting
the dust extractor off to allow dust to settle.
2. Unlatch the tank latches
Fig. F
4
3. Remove the dust extractor head
Fig. G
16
4. Empty the contents of the tank into a suitable container.
5. Clean or change HEPA filters
section of this manual.
6. Inspect machine for damage by foreign objects. Contact
the nearest D
WALT authorized service center for
e
replacement of damaged or missing parts.
7. Replace dust extractor head onto the tank.
nOTE: The dust extractor head only fits in one
orientation as shown in Fig G.
8. Latch all four latches securely.
nOTE: Inspect water sense probes
English
3
to the Off (O) position
4
.
from the tank
.
6
16
6
18
. Refer to HEPA Filter
27
during dust