5.
TECHNICAL DETAILS GV60
Gas valve type
Burner control
Ignition
Gas connection
Unit category
Pilot flame
Combustion gas discharge
and Combustion air supply
5. TECHNICAL DETAILS GV60
C
B
A
D
NOTICE
SEALED PARTS MAY NOT BE ADJUSTED.
: Mertik GV60
: B6R R8U
: Remote control operation and Piezo ignition
: 3/8 "(External) A = Gas inlet B = Gas outlet rear burner
C = Gas outlet front burner D = Thermocouple connection
E = pilot burner connection
: C11-C31-C91
: SIT 3 flames
: Concentric: Ø130 / 200mm
E
Side inlet
Side outlet
Pressure regulator
Main valve knob
Inlet pressure
Bottom outlet
Outlet pressure
Pilot gas adjustment
MAN knob
Ignition connection
Thermocouple
connection
Bottom inlet
Page.7