Thermocet TRIMLINE Serie Instrucciones De Instalación página 17

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

No ACTION
3.
Continuous spark
Spark will occur each
second.
OK
4.
Pilot lit.
OK
5.
Sparking stops after
pilot is lit
OK
Possible problem/cause
NO
Ignition components not operating
properly.
NO
IGN sequence stops, no pilot flame.
No reaction to transmitter command
(receiver does not react).
NO
IGN sequence stops, no pilot flame.
Transmitter command is possible.
NO
TC and SW cable reversed.
Impulse magnet not operating properly. Replace gas valve.
Short between interrupter and SW
cable.
No gas magnet unit drops after 30
second audible count).
Interrupter
NO
Short between interrupter and TC cable. Check connection to interrupter,
Electronic measuring amplifier defective. Replace receiver.
Solution
Check connection between cable & IGN
electrode.
Check IGN electrode spark gap.
Check IGN electrode for discharge to
ground (break in ceramic).
Check IGN cable for damage
Increase distance between IGN cable and
all metal parts. Check that spark does
not discharge to ground at location of
spark plug connection. Shorten cable if
possible. If applicable, provide extra
insulation with silicon hose etc.
Press RESET button, see instructions.
Add ground wire between pilot burner
and gas valve.
Do not coil the IGN cable.
Shorten IGN cable if possible.
IGN sequence stops, no pilot flame.
Transmitter command is possible.
Check connection of cable to receiver
and interrupter, see fig. 1.
Check connection to interrupter.
Check gas supply to gas valve.
Receiver
see fig. 1
Page.16
Tabla de contenido
loading

Tabla de contenido