1-
Find a leveled and flat surface surface, such as table before start calibration.
2-
Turn the device off.
3-
Tap and hold the
4-
You could press the
5-
You can also put the device straightly and make the LCD face to you to start calibration.
6-
Press
button to start self-calibration (1
7-
The short beep is notification for getting ready to start.
8-
The long beep is notification for calibration finished, than turn the device 180 degree straightly.
9-
Press
button to continue calibration procedure (2
10- When the step 2 is done, lay the device down on the table.
11- Press
button to continue calibration procedure (3
12- When the step 3 is done, turn the device 180 degree.
13- Press
button to continue calibration procedure (4
14- After calibration, the device will be turned off automatically.
Calibration Mode
rd
3
step [CAL 3]
Picture 11 – Calibration Mode
Calibration of Angle Sensor
and turn the device on to enter calibration mode [CAL0].
button to restore to default.
st
step) [CAL1].
st
1
step [CAL 1]
th
4
step [CAL 4]
nd
step) [CAL2].
rd
step) [CAL3].
th
step) [CAL4].
nd
2
step [CAL 2]
LMXP-100 ENG
CAL 3
10