Adjusting Spray Pattern; Setting The Product Flow Rate - WALTHER PILOT GM 1030P Instrucciones De Servicio

Ocultar thumbs Ver también para GM 1030P:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 228
VERSION 12/2020
OPERATING MANUAL

7.3.1 ADJUSTING SPRAY PATTERN

The spray pattern can be optimally adjusted to suit the object being sprayed using the
shaping air regulator (1). The illustration shows the influence of the shaping air regulator (1)
on the spray pattern.
a
Opening the
shaping air
regulator
Description
a
If the shaping air regulator (1) is rotated counterclockwise, the spray pattern is
widened and increasingly oval shaped.
b
If the shaping air regulator (1) is rotated clockwise, the spray pattern is narrowed
and increasingly round.

7.3.2 SETTING THE PRODUCT FLOW RATE

The flow rate can be adjusted by screwing the needle stroke regulator (1) in or out. The flow
rate is increased by rotating it in a counterclockwise direction and is decreased by rotating it
in a clockwise direction. If the desired flow rate is reached, the needle stroke regulator (1) can
be fixed using the lock (2), to prevent adjustments.
Note: the desired flow rate is primarily to be specified by selecting the corresponding
nozzle. The needle stroke regulator (1) only serves to make fine adjustments.
1
More product
B_07089
DOC2422648
1
Closing the
shaping air
B_07088
regulator
2 1
1
Less product
b
PILOT GM 1030P
25
Tabla de contenido
loading

Productos relacionados para WALTHER PILOT GM 1030P

Este manual también es adecuado para:

Gm 1030p adh

Tabla de contenido