HSW−...−AP/A S
Please note
For HSW−...−AS with electric motor:
Movement to a fixed stop creates impulsive loadings in the drive train. This can
cause damage to the gears, for example.
S Always use reduced energy during reference runs to the fixed stops
(1/9 in Fig. 1).
The rubber buffers in the fixed stops are only for silencing.
Please note
For type HSW−...−...W−...:
S Please observe the warnings and instructions in the operating instructions
for BW−HSW−...
Pressurize the add−on components.
S
If necessary, carry out a separate test run to check that the add−on compo
S
nents are functioning correctly.
Attachment
components
Without work load
With load
Fig. 26
Pressurize the drive in one of the following ways as desired:
S
slow pressurization of one side
simultaneous pressurization of both sides with subsequent exhausting of
one side
Please note
The swivel module DSM−... for HSW−...−AP may only be operated unmodified as
supplied from the factory and with the protective cap (if present).
48
Tests
Check the correct assignment of the compressed air
connections
Gripping speed
Function of the proximity switches
Check that the work load is gripped firmly
Festo HSW−...−AP/AS 0707a English