Table "A": Technical Data
EQUH-PF Model
Nominal cooling capacity (*)
rd
E.E.R. (3
step, 100%)
rd
E.E.R. (3
step, 100%)
EN 14511 05/11 (250kPa residual)
E.S.E.E.R.
E.S.E.E.R. +
E.S.E.E.R. EN 14511 05/11 (250kPa residual)
Nominal heating capacity (**)
C.O.P.
C.O.P EN 14511 05/11 (250kPa residual)
EER (****)
C.O.P (****)
rd
Sound power level (3
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Fan maximum available static head
Water side heat exchanger water content
Water side heat exchanger nominal flow (*)
Water side heat exchanger nominal pressure drops (*)
Water side heat exchanger nominal pressure drops (**)
P1 residual head (*)
P2 residual head (*)
ASP1 residual head (*)
ASP2 residual head (*)
Water tank content (ASP1/ASP2)
Amount of R410A refrigerant
Amount of Polyester oil
Electrical data
Absorbed power in summer mode (*) (■)
Absorbed power in winter mode (**) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary power supply
Control power supply
Nominal current in summer mode (*) (■)
Nominal current in winter mode (**) (■)
Maximum current (■)
Starting current (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Width (a)
Height (b)
Depth (c)
Heat exchanger inlet/outlet connections
DS/RC100 inlet/outlet connections
(*) In the following conditions: Condenser inlet
air temperature 35°C; chilled water temperature
7°C; temperature differential at evaporator 5°C.
(**) In the following conditions: Evaporator inlet
air temperature 7°C D.B., 6°C W.B.; hot water
temperature 45°C; temperature differential at
condenser 5°C.
(***) Sound power level in dB(A) on the basis of
measurements taken in accordance with RS
6/C/005-2009 and UNI EN-ISO 9614/1. The
noise data refers to the units without the pump.
(****) Energy indices for EQUH-PF versions
without accessories, calculated in compliance
with that envisaged by EN 14511:2004;
(■) Pumps excluded.
step, 100%) (***)
Note:
The E.E.R. and C.O.P calculation does not
consider the absorption of the pumps.
The EER, ESEER and COP calculations
according to EN 14511 05/11 (250kPa residual)
refer to the versions without pumps.
The machine decreases its noise below the
nominal value indicated in the table when the
outdoor air temperature is below 35°C and
condensation control is present.
The starting current reduces by 25% with the
SFS accessory
If the INS accessory is present, the sound
power Lw decreases by 2 dB(A).
233
238
kW
32,5
38,8
2,36
2,93
2,95
3,65
3,07
3,81
3,44
4,25
5,35
6,02
kW
37,5
41,7
2.72
3,13
3,43
3,93
3,47
4,25
4,70
5,25
dB(A)
82
82
2/2
2/2
1
1
n° x kW
1x2.08
1x2.08
m³/h
13000
13000
Pa
250
250
l
3,20
3,20
m³/h
5581
6674
kPa
28
56
39
66
kPa
136
130
kPa
231
227
kPa
107
87
kPa
202
184
l
150
150
233
238
kW
13,8
13,2
13,8
13,3
kW
0,7/1,5
0,7/1,5
V-ph-Hz
V-ph-Hz
V-ph-Hz
A
21,8
25,4
A
20,8
23,4
A
27,8
31,4
A
117
117
A
2,2/3,5
2,2/3,5
233
238
mm
870
870
mm
1920
1920
mm
2600
2600
Ø
1-1/4"
1-1/4"
Ø
1-1/4"
1-1/4"
54
ENCLOSED DOCUMENTS
245
250
260
42,6
50,6
58,1
2,46
2,39
2,37
2,91
3,25
3,08
3,08
2,98
2,96
3,59
3,46
3,43
5,59
5,43
5,40
47,8
55,8
62,2
2,79
2,62
2,66
3,33
3,58
3,52
3,78
3,88
3,80
4,73
4,92
4,73
83
85
85
2/3
2/3
2/3
1
1
1
1x2.10
2x2.15
2x2.23
13000
26000
26000
250
250
250
3,80
4,40
5,10
7300
8700
10000
32
32
33
42
42
43
125
115
105
198
191
186
118
105
90
190
181
166
150
150
150
See serial number plate
See compressor plate
245
250
260
17,3
21,2
24,5
17,1
21,3
23,4
0,7/1,5
0,7/1,5
0,7/1,5
400 – 3+N – 50
230 – 1+N – 50
24 – 1 – 50
22,9
32,4
38,0
22,6
30,8
35,5
36,7
45,7
50,4
132
152
218
5,1/8,6
5,1/8,6
5,1/8,6
245
250
260
870
870
870
1920
1920
1920
2600
2600
2600
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
265
61,9
2.30
2,91
2,88
3,39
5,24
67,9
2,59
3,31
3,80
4,66
85
2/3
1
2x2.23
26000
250
5,70
10600
31
41
97
172
81
156
150
265
26,9
26,2
0,7/1,5
41,3
39,5
55,2
224
5,1/8,6
265
870
1920
2600
1-1/4"
1-1/4"