• Move your RUBILASER L2D2 until it is 15 cm.
(6") from wall B. Mark the intersection point
of the two laser lines on wall B, and name this
point B2.
• Turn your unit 180º and mark the intersection
point of the two laser lines on wall A. Name
this point A2.
• Measure the distance between A1 and A2 and
between B1 and B2. If the distances are equal,
the laser is correctly calibrated. If there is a
difference greater than 3.17 mm. (1/8"), your
unit is uncalibrated.
Vertical:
• Choose a doorframe, where there should be
a distance of 2.5 m free of obstacles or walls
on each side.
• Place your unit at a point A (2.5 m. from the
door) and activate it. Select the vertical laser
line.
• Mark a first point B on the ground over the
projected line 2.5 m. from the point A where
your unit is located.
• Mark a second point C on the ground over
the same projected laser line 5 m from A.
• Without moving your RUBILASER L2D2,
mark a third point D located on the upper
doorframe.
• Take your unit and move it to point C. Align the
vertical laser beam EXACTLY with point B.
• Observe the distance between the laser beam
and point D. If it is equal to or less than 16
mm. (1/6"), your unit is correctly calibrated.
ENGLISH
PRECAUTIONS
• Only use the product for those jobs for which
it was intended. Keep out of the reach of chil-
dren.
• Do not look directly into the laser ray.
• Do not take the instrument apart or make any
type of modification.
• Any repair and/or calibration must only be
carried out by the manufacturer.
• Do not store the product in very warm or
very cold places. Likewise, always store it in
areas that are free of dust and humidity.
• Do not bump your unit or throw it on the
ground.
EC CERTIFICATION
The company, Germans Boada S.A., hereby
certifies that the product RUBILASER L2D2
complies with the following regulations:
• European Directives 89/336/CEE, and 92/31/
CEE
• Rohs Directive 2002/95/CEE
• EN55022:1998+A1:2000+A2:2003
• EN61000-3-2/-3; EN60825-1/1994
• E N 5 5 0 2 4 : 1 9 9 8 + A 1 : 2 0 0 0 + A 2 : 2 0 0 3 ,
(EN61000-4-2/-3/-4/-5/-6/-11)
• EN61010-1:2001+CORRIG.1+2
• EN60825-1:1994+A1+A2+CORRIG.
This declaration will no longer be valid if the
product is not used in accordance with the afore-
mentioned or if any alterations are made to it.