Cabinet; Push And Pull Intensifiers - avdel 07287 Manual De Instrucciones

Máquina hidroneumática
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

S e r v i c i n g t h e To o l
Tr i g g e r A s s e m b l y
Item numbers in bold refer to the General Assembly drawing and Parts List on pages 16-17.
Using a spanner, undo Locknut 7 and remove Trigger 6, 'O' Ring 15, and Spring 8 from Handle 1.
Assemble in reverse order of dismantling.
C a b i n e t
Item numbers in bold refer to the General Assembly drawing and Parts List on pages 18-19.
The cabinet comprises two Intensifiers 4 and 25, a pilot Valve 23, a Pressure Regulator and Filter Assembly 45 and an Air
Pressure Indicating Assembly 53 together with the air hoses internal to the cabinet.
Servicing is limited to removal/replacement of complete assemblies and the renewal of seals within the pilot valve.
To dismantle the cabinet it is necessary to extract the Base Plate 61 and the components installed on it. This is possible after
disconnecting all hoses and removing items restricting the withdrawal of the base plate.
P u s h a n d P u l l I n t e n s i f i e r s
Item numbers in bold refer to the General Assembly drawing and Parts List on pages 18-19.
To remove Intensifiers 4, 25 and Oil Reservoir 36, disconnect the oil hose using two spanners, (be prepared for oil spillage from
hose/ intensifier), then remove the hoses (quick release connectors) connecting the intensifier to the pilot valve.
Using a spanner, remove the two nuts and associated washers securing the intensifier to the baseplate.
Lift intensifier clear of cabinet.
Replacement is in reverse order of removal.
Priming is ALWAYS necessary after the tool has been dismantled and prior to operating.
14
I M P O R T A N T
Check the tool against daily and weekly servicing