Container installation procedure
4A
• Remove the screws "B" and carefully extract
the P.C.B. card "C" from the container re-
membering to store it somewhere safe from
dust and possible damage.
4B
• Using the container as a template mark the
four points at which the fastening holes are to
be drilled;
• Fasten the container using four screws and
raw plugs "G" and insert the screw covering
plugs "H".
• Insert the pipe fittings "D"
that they are fastened correctly.
4C
• Re-insert the electronic card into the con-
tainer and fasten down using the screws "B"
(fig.4A)
• Insert the rigid electrical connection pipes "I"
into the cable tubes. The 230V~/400V3 power
cables should be passed through pipes 1 and
2 (see figure) so as to separate them from the
low voltage wires which should be passed
through pipes 3 and 4.
• Carry out the electrical connection following
the attached wiring diagram (see fig. 5).
All rights reserved. Unauthorised copying or use of the information contained in this document is punishab
Drawing number :
Product Code :
Draft :
P.j.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
(fig. 4A)
and check
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Drawing number :
Product Code :
Draft :
P.j.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
9
Description :
DM0138
Inserimento scheda PRG383
PRG
Date :
2-04-98
Description :
DM0135
Installazione contenitore PRG
LPRG
Date :
2-04-98
A
D
C
E
F
G
M
1 3 0 M
1
2
3
4
4
4
B
H
I