EN
MESS. DISPLAY
DESCRIPTION
Over voltage error
E08
temporary.
Over voltage error
E09
definitive.
Absence of network
E10
power (in memory)
E11
Power error.
E12
Memory error.
E13
Configuration error.
E99
Undefined error.
485E
Communication error.
CHAPTER 7
RESETTING AND FACTORY SETTINGS
7.1 GENERAL SYSTEM RESET
ATTENTION
Press only as a last resort to restart the system.
Triggers a general module reset and reloads set values saved in eeprom. Press as a last resort only in order to restart the module. If, for
whatever reason, the module becomes blocked, wait approximately 10 seconds for the module itself to automatically launch a general
reset. If this does not reset the system, use this key and contact a customer care centre.
Reset key sequence, press SET for 20 seconds.
36
This error condition occurs when the voltage
exceeds by 10% the nominal voltage (230V).
This alarm condition closes the J3 contact on
the power board for possible external signals
(alarm light, siren, etc.)
A definitive over voltage error occurs after
a temporary over voltage error is repeated 5
times.
This condition occurs following a network
absence.
This condition indicates a motor power
absorption error in terms of its running status.
This error occurs when eeprom is unable to load
the parameters which have been entered.
This error occurs when the control board cannot
correctly communicate with the power part. This
alarm condition closes the J3 contact on the
power board for possible external signals (alarm
light, siren, etc.).
This error occurs when an unforeseen error
takes place.
This signal refers to pump units and is indicated
when the devices are not communicating
correctly.
ACTION
In this case, the module will attempt to restart normal
functioning after 1 minute and will repeat the procedure
up to five times. Press the button START/STOP or cut
the power off and wait until the LINE Led switches off
and after which restart the system.
If the error occurs again, contact customer care.
Press the START/STOP button or cut off power and wait
until the red Led LINE goes off, then power again to
reset the system.
If the error occurs again, contact your nearest customer
care centre.
Wait for a few minutes. If the signal remains, press
the button START/STOP or cut the power off and wait
until the LINE Led switches off and after which restart
the system.
Press the button START/STOP or cut the power off and
wait until the LINE Led switches off and after which
restart the system.
If the error occurs again, contact your nearest
assistance centre.
Wait for a few minutes. If the signal remains, contact
your nearest customer care centre.
Press the button START/STOP or cut the power off and
wait until the LINE Led switches off and after which
restart the system.
Check the communication cable. If the error occurs
again, contact your nearest customer care centre.