Aqua Medic EcoDrift 4.3 Manual De Instrucciones página 10

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
You can choose between the following programs:
Fig. 3, No. 5: Frequency and speed can be adjusted. By using the SPEED button, the power can be varied
continuously between 30 and 100%. The pulse rate can be changed using the LOW / HIGH buttons.
Fig. 3, No. 6: The flow is slowly increased and then slowly reduced again.
Fig. 3, No. 7: random generator. The flow changes according to the random principle.
Fig. 3, No. 8: Constant flow. The power can be set with the arrow keys.
Fig. 3, No. 9: Cross-Flow (can only be set via the app).
Fig. 4: „AUTO"
"AUTO" appears in the display when the associated pump runs in timer mode via the App which means time-
controlled. The controller's keyboard is out of operation. If the pump is to be controlled via the controller again,
keep both arrow keys pressed until "AUTO" disappears on the display.
6. App Control
Please refer to www.aqua-medic.de for the manual. Add the QR Code to the App.
7. Cleaning and Maintenance
From time to time, the pump needs to be cleaned. In particular, the impeller could be stuck on the axle so that
the pump stops operating. First of all, remove the pump assembly from the holder (Fig. 1, No. 6). Then, remove
the rubber gaskets (Fig. 1, No. 4). Twist the filter basket (Fig. 1, No. 1) and remove it from the pump housing
(Fig. 1, No. 3). Hold the pump assembly with your left hand. With your right hand, twist the filter basket
counterclockwise to unlock it from the pump housing. The filter basket can be locked in various positions. Ideally,
the cable should point vertically upwards.
After removal of the basket, the entire impeller unit can be pulled out. All components can be cleaned under
running water and be re-assembled again. During assembly, make sure that the impeller rotates on the axle resp.
in the ceramic bearing and the ceramic shaft fits properly into the filter basket's socket. The rubber bearing has
to be inserted far enough. Take care that is doesn't squeeze the impeller and block it.
8. Failures
Regularly clean the pump from dirt and lime deposits. We recommend Aqua Medic variocare. The ceramic axle
of the impeller must rotate freely in the ceramic socket. If the cleaning is not done often enough, it may cause
engine failure.
The following errors can appear in the display:
ER01: Current consumption too high
ER02: Temperature too high
ER03: Pump runs dry
ER04: Impeller blocked
ER05: Voltage too high
Turn off the pump and clean it. If the errors occur again, please refer to your dealer, as mentioned in the warranty
conditions.
10
loading

Este manual también es adecuado para:

Ecodrift 8.3Ecodrift 15.3Ecodrift 20.3