Dickey-John MINI GAC AND Manual Del Operador página 33

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

OPERATOR'S MANUAL
50
51
lb/Bu
52
kg/hl
52
lb/Bu
54
kg/hl
54
30 / ERROR CODES
ERROR 50
Probable Cause
Error 50 displays if the weight measurement during the Empty Cell
test indicates a mass that exceeds 250 grams.
Corrective Action
1. Ensure the Loader cup is removed and not on top of tester.
2. Make sure cell is empty.
3. Press the Enter button and perform a new test.
ERROR 51
Probable Cause
Error 51 displays if the load cell output used to measure the grain
weight sample is too close to the upper or lower limits of the strain
gauge. The unit is not capable of making accurate measurements
and will no longer operate other than to turn off.
Corrective Action
1. Unit is not operational. Return to DICKEY-john for service.
ERROR 52
Probable Cause
Error 52 displays when the calculated Test Weight of the sample is
50% less than the Average Sample Weight.
Corrective Action
1. Ensure the Loader cup is removed and not on top of the
tester during the empty cell test. Press the Enter button and
perform a new test.
ERROR 54
Probable Cause
Error 54 displays when the calculated Test Weight of the sample is
150% greater than the Average Sample Weight.
Corrective Action
1. Ensure the Loader cup is removed and not on top of the
tester during the full cell test. Press the Enter button and
perform a new test.
mini GAC
11001-1464 Rev C
®
Tabla de contenido
loading

Productos relacionados para Dickey-John MINI GAC AND

Este manual también es adecuado para:

Mini gac plus

Tabla de contenido