SETTING THE OPERATIONAL LOGIC
By simply altering the dip-switches located on the card. it is
possible for the control unit to use several different operational
logic states.
The functions associated with each dip-switch are described
below.
DIP
DESCRIPTION
ON
UP / DOWN operation
1
OFF
STEP by STEP operation
ON
Light output TIMER operation
2
OFF
Light output BISTABLE operation
UP / DOWN operation
The commands subsequent to start on inputs C1 (open) and C2
(close) cause the following sequence of operations:
OPENING
STAND-BY
CLOSING
STEP by STEP operation
Successive start commands result in the following events, in order:
open - stop - close - stop...
Control inputs:
C1: motor 1 control
C2: NOT USED
Light output TIMER operation
The light output can be controlled by using the special LIGHT key
on the transmitters memorised in the control unit, or by means
of an external key connected between terminals 2 and 6.
To program the light output in TIMER mode, proceed as follows:
1. Set DIP 2 to the ON position
2. Press and release the MOT key: the MOT1 LED lights up.
3. Press the MOT key once again: the LIGHT LED + the LEDs
corresponding to the time value set light up.
LED1 0.5 seconds
LED2 5 minutes
LED3 10 minutes
LED4 15 minutes
LED5 30 minutes
4. To increase the time, press the + key
5. To reduce the time, press the - key
6. To exit program mode, wait for 4 seconds without pressing
any of the keys: the LEDs are turned off.
Light output BISTABLE operation
The light output can be controlled by using the special LIGHT key
on the transmitters memorised in the control unit, or by means
of an external key connected between terminals 2 and 6.
To program the light output in BISTABLE mode, simply set DIP 2
to the OFF position.
C1
C1
STOP
C2
C2
C1
C1
STOP
C2
C2
SENSOR LEVELS
The sensors may be set to different levels depending on the
specific needs of each installation. The sensor level may be
examined by means of the 5 dedicated LEDs located on the card.
The levels shown by means of the LEDs and the corresponding
real parameters are shown below (the default values are shown in
boxes):
Leds ON
Wind
sensor
1
10 km/h
2
15 km/h
3
20 km/h
4
30 km/h
5
40 km/h
SETTING SENSOR LEVELS USING THE
KEYS ON THE CONTROL UNIT
To alter the sensor level for motor 1, proceed as follows:
1. Press and release the MOT key: the MOT1 LED lights up
2. Press and release the SENS key until the LED relating to the
desired sensor lights up.
3. The 5 dedicated LEDs show the current sensor level.
4. Press the + key to increase the level
5. Press the - key to reduce the level
6. Press the SENS key to change sensors
7. To exit programming mode, press the SENS key once after
having set the temperature sensor level, or wait for 4 seconds
without pressing any of the keys: the LEDs indicating the
sensors and the levels are turned off.
WARNING: if no other buttons are pressed for 4 seconds, the
control unit exits from programming mode.
INTERVENTION OF THE WIND SENSOR
Whenever the wind speed exceeds the set threshold value for at
least 5 seconds, the control unit closes the shade and blocks the
controls (no further commands accepted) for 8 minutes.
INTERVENTION OF THE SUN SENSOR
If the light intensity exceeds the set threshold value for at least 8
minutes, the control unit opens the shade.
If the light intensity drops below the set threshold value for at
least 8 minutes, the control unit closes the shade. The keypad
or remote control commands have priority over the sun sensor.
Operation of the sun sensor may be disabled by means of a switch
connected to input 3 (SUN ON/OFF).
- 19 -
Sun
Temperature
sensor
sensor
2 klux
Disabled
5 klux
0° C
10 klux
5° C
20 klux
10° C
40 klux
15° C