Do not connect the appliance to flues (from boilers, fireplaces, etc.). Make sure the mains volt-
age corresponds to the values on the rating plate located inside the range hood. The minimum
safety distance between the cooktop and the range hood must be at least 65 cm.
Never cook on "open" flames under the range hood.
Check deep-fryers during use: superheated oil may be flammable.
- Ensure there is adequate ventilation of the room when the rangehood is used at the same
time as appliances burning gas or other fuels.
- Do not flambe under the rangehood
- The exhaust air must not be discharged into a flue which is used for exhausting fumes from
appliances burning gas or other fuels.
- Ensure that all regulations concerning the discharge of exhaust air have been fulfilled before
you use the appliance.
Before performing any cleaning or maintenance operations, disconnect the appliance by un-
plugging it or using the main switch. The manufacturer disclaims all liability for any damage
that may be directly or indirectly caused to people, things and animals due to the failure to
follow all the instructions provided in this booklet and above all the warnings relating to the
installation, operation and maintenance of the appliance.
L
WARRANTY
The new equipment is covered by warranty. The warranty conditions are provided by the
distributor.
The manufacturer is not liable for any inaccuracies in this booklet resulting from printing or
transcription errors. The manufacturer reserves the right to modify its products as it consid-
ers necessary or in the interests of the user, without compromising their essential safety and
operating characteristics.
M
ASSEMBLY INSTRUCTIONS
M1
SUSPENDED ISLAND HOOD ASSEMBY INSTRUCTIONS
(Fig. A)
1) Verify that the ceiling is arranged for installing the hood range power supply, according to
the standards in force. Disconnect the power supply of the electrical system that powers
the range hood.
2) Insert:
- the 4 steel cords (C1) in the 4 holes (F1) of the ceiling support (SC);
- The power cable of the range hood system (CAI) inside the hole (F2) of the ceiling support
(SC).
3) Connect the power supply terminal (MA) to the power cable (CAI) complying with the phase
provisions, neutral and earth (see sect. D).
(Fig. B)
1) Fasten the support (SC) to the ceiling using 4 fischer of Ø 8 mm and relative screws V1.
2) Insert the steel cords (C1) inside the holes of the support cover plate (C).
(Fig. C)
1) Detect the height (Y) of the range hood from the ceiling, considering the height X=60/65 cm
and that (Z) varies depending on the model of the range hood.
(Fig. D)
1) After having determined the height (Y), cut the lower part of the steel cords (C1) in excess.
2) Loosen the cable-lock (BC) by rotating the knurled cylinder anti-clockwise;