If needing to work on damp ground, in order
stop the suction motor by pressing the suction
machine.
Before leaving the machine, make sure that
parking brake is engaged and that the ignition
key has been take out of the instrument board.
FURTHER PERFORMANCES
OF THE MACHINE
FEATURING AN ENGINE
The version featuring an engine can guarantee
out or when working in closed environments.
Operating autonomy in this case will depend
on the capacity of the batteries installed, on the
intensity of the chosen work program and on
initial battery charge.
To guarantee the working life of the batteries,
the machine features some safety systems:
•
when the battery voltage drops below
20.5 volts, all of the functions except
for drive are automatically stopped.
When this situation occurs, recharge the
batteries or turn on the engine.
•
Protection against battery overcharging:
this machine, having a current generator
with an electronic circuit that acts as a
voltage regulator, ensures the batteries
are correctly charged without damaging
them due to excessive load.
When the batteries are fully charged,
this system automatically ensures no
additional charge will be applied.
the results obtained on the energy balance of
our hybrid system (DUAL POWER system),
this can work in complete autonomy without
the need to stop the machine and externally
recharge the battery pack. Repeated tests
with the three work programs (P1, P2, P3) on
asphalted surfaces and with normal working
slopes have demonstrated that the machine
operates in complete autonomy.
However, being the machine designed also for
heavy duty working conditions (slopes of over
20%, extremely rough surfaces to clean), the
batteries may need to be recharged.
In this case, it is advisable to use an electronic
the batteries installed.
SAFETY THERMOSTAT
The safety thermostat is located in the position
shown.
thermostat will stop the suction fan. Proceed
as follows:
•
take the machine to a safe area.
•
open the debris bin and remove the
heat source.
EN
14