Danfoss AK-PC 710 Manual Del Usuario página 68

Control de capacidad
Tabla de contenido
c35
Load shed limit 1
c36
Override limit Po
c37
Override delay 1 min
c38
Pump down
c39
Initial start time
c40
Compressor 1 size
c41
Compressor 2 size
c42
Compressor 3 size
c43
Compressor 4 size
c44
Compressor 5 size
c45
Compressor 6 size
c46
VSD Min speed Hz
c47
VSD Start speed Hz
c48
VSD Max speed Hz
c49
Emergency cap day%
c50
Emergency cap. night%
Compressor timers
c51
Comp. 1 Min. ON-time
c52
Comp. 2 Min. ON-time
c53
Comp. 3 Min. ON-time
c54
Comp. 4 Min. ON-time
c55
Comp. 5 Min. ON-time
c56
Comp. 6 Min. ON-time
c57
Comp. 1 Min. OFF-time
c58
Comp. 2 Min. OFF-time
c59
Comp. 3 Min. OFF-time
c60
Comp. 4 Min. OFF-time
c61
Comp. 5 Min. OFF-time
c62
Comp. 6 Min. OFF-time
c63
Comp. 1 Recycle time
c64
Comp. 2 Recycle time
c65
Comp. 3 Recycle time
c66
Comp. 4 Recycle time
c67
Comp. 5 Recycle time
c68
Comp. 6 Recycle time
Neutral zone control
n04
Xp P-band K
n05
Tn Integr. time s
n20
Kp Po
n52
Control mode
n53
Manual capacity %
n54
VSD Start speed %
n55
VSD Min. speed %
68
W
Set max compressor capacity limit for load shed input
W
Any load below the limit value is freely permitted. If the suction pressure
Po exceeds the value, a time delay is started. If the time delay runs out, the
load limit is cancelled
W
Max. time for capacity limit, if Po is too high
W
Select whether a pump down function is required on the last running
compressor
W
The time after start-up where the cut-in capacity is limited to the first
compressor step.
W
"Set the nominal capacity for the compressor in question.
For compressors with variable speed drive the nominal capacity must be
set for the mains frequency (50/60 Hz)
Set the nominal capacity for the compressor in question."
W
Set the nominal capacity for the compressor in question.
W
Set the nominal capacity for the compressor in question.
W
Set the nominal capacity for the compressor in question.
W
Set the nominal capacity for the compressor in question.
W
Set the nominal capacity for the compressor in question.
W
Min. speed where the compressor must cutout
W
Minimum speed for start of Variable speed drive (Must be set higher than
"VSD Min. Speed Hz")
W
Highest permissible speed for the compressor motor
W
The desired cut-in capacity for daily use in the case of emer¬gency opera-
tions resulting from error in the suction pressure sensor/ media tempera-
ture sensor
W
The desired cut-in capacity for night operations in the case of emergency
operations resulting from error in the suction pressure sensor/ media
temperature sensor.
W
Minimum duration of ON period
W
Minimum duration of ON period
W
Minimum duration of ON period
W
Minimum duration of ON period
W
Minimum duration of ON period
W
Minimum duration of ON period
W
Minimum duration of OFF periode
W
Minimum duration of OFF periode
W
Minimum duration of OFF periode
W
Minimum duration of OFF periode
W
Minimum duration of OFF periode
W
Minimum duration of OFF periode
W
Minimum period between two succecive compressor starts
W
Minimum period between two succecive compressor starts
W
Minimum period between two succecive compressor starts
W
Minimum period between two succecive compressor starts
W
Minimum period between two succecive compressor starts
W
Minimum period between two succecive compressor starts
W
Proportional band for condenser P/PI controller
W
Integration time for condenser PI controller
W
Ampliflication factor for compressor capacity control
W
"0: MAN (The condenser capacity will be controlled manually)
1: OFF (The capacity control will be stopped)
2: AUTO (The capacity is controlled by the PI controller)"
W
Manual setting of condenser capacity
W
Condenser minimum speed for start of speed control (Must be configu¬red
higher than "VSD Min. Speed %")
W
Condenser minimum speed whereby speed control is cut-out (low load).
Control de capacidad RS8FT405 © Danfoss 03-2013
0 - 100%
100%
-50,0 °C - 80,0 °C
80,0 °C
0 - 240 min
10 min
0: No
0: No
1: Yes
0 - 900 sec
120 sec
0,0 - 99,9 kW
0 kW
0,0 - 99,9 kW
0 kW
0,0 - 99,9 kW
0 kW
0,0 - 99,9 kW
0 kW
0,0 - 99,9 kW
0 kW
0,0 - 99,9 kW
0 kW
0,5 Hz
60,0 Hz
20,0 Hz
60,0 Hz
40,0 Hz
120,0 Hz
0 - 100%
50%
100%
25%
0 - 60 min
0 min
0 - 60 min
0 min
0 - 60 min
0 min
0 - 60 min
0 min
0 - 60 min
0 min
0 - 60 min
0 min
0 - 30 min
0 min
0 - 30 min
0 min
0 - 30 min
0 min
0 - 30 min
0 min
0 - 30 min
0 min
0 - 30 min
0 min
1 - 60 min
6 min
1 - 60 min
6 min
1 - 60 min
6 min
1 - 60 min
6 min
1 - 60 min
6 min
1 - 60 min
6 min
0,0 - 100,0 K
10,0 K
30 - 600 sec
180 sec
0,1 - 10,0
2
0: Manual control
2: Auto
1: OFF
2: Auto
0 - 100%
0%
0,0 - 40,0 %
20,0%
0,0 - 40,0 %
10,0%