ELECTRICAL REQUIREMENTS cont.
POWER SUPPLY CORD
Wiring Requirements
• 115-Volt (103.5 min. to 126.5 max.)
• 0 to 12 amps
• 15-Amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
RECOMMENDED GROUNDING METHOD
This air conditioner must be grounded. This air conditioner is equipped with
a power supply cord that has a 3 prong grounding plug. The power supply
cord must be plugged into a mating, grounded 3 prong outlet, and grounded
in accordance with all local codes and ordinances. If a mating outlet is not
available, it is the customer's responsibility to contact a qualified electrician
and ensure that a properly grounded 3 prong outlet is installed.
POWER SUPPLY CORD
NOTE: Your air conditioner's plug may differ slightly in appearance from the one shown.
A. Reset button
B. Test button
This room air conditioner is equipped with an a leakage current detection interrupter ( LCDI)
power supply cord required by UL. This power supply cord contains a current detection device.
If the power supply cord is crushed, this device will detect current leakage and power will be
disconnected from the air conditioner. If this power supply cord is damaged, it cannot be
repaired and must be replaced with a cord from the product manufacturer. If the power supply
cord is damaged call Haier Customer Service: 1-877-337-3639.
PAGE 8
(See Fig.5)
A
B
Fig. 5
INSTALLATION REQUIREMENTS
(See Fig.4)
Fig. 4