Function
Temperature
(Fahrenheit)
Temperature
(Celsius)
FREQUENCY (AUTO-RANGING)
99.99Hz
999.9Hz
9.999kHz
99.99kHz
999.9kHz
Measurement Range: 10Hz – 1MHz
≤100kHz – 250mV rms ≤Input amplitude ≤20V rms
>100kHz – 1MHz: 600mV rms ≤Input amplitude ≤20V rms

DUTY CYCLE

0.1% to 99.9%
Frequency width: ≤100kHz
OTHER MEASUREMENT APPLICATIONS
• Diode Test: Max. 1.0mA, open circuit voltage ~ 2.5V DC
• Continuity Check: Test current 0.5mA
• Sampling Frequency: 3 samples per second
• Low Impedance (Low Z): Input impedance: >3kΩ
• NCVT: 24V to 1000V AC
• Auto Power off: After ~10 minutes of inactivity
• Overload: "OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use verify meter operation by measuring a known voltage
or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT IV rated test leads.
• Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
4
ELECTRICAL SPECIFICATIONS
Range
°
°F
-40
to 32
33°
°F
to 932
933°
°F
to 1832
-40° to 0°C
1° to 500°C
501° to 1000°C
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
0.1%
Max input: 600V RMS
WARNINGS
Resolution
°F
0.1
°F
1
°C
0.1
°C
1
±(1.0% + 5 digits)
Reference only
Accuracy
°F
±(2.0% + 6
)
°F
±(1.0% + 2
)
°F
±(1.5% + 6
)
°C
±(2.0% + 3
)
°C
±(1.0% + 1
)
°C
±(1.5% + 3
)