EdilKamin STATUS PLUS Instalación Uso Y Mantenimiento página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
INSTALLATION INSTRUCTIONS
External air inlet (figures E-F-G)
It is absolutely necessary, without
exception, to build a connection to the
outside with a cross-section of 300 cm²
for the proper functioning of the fire-
place.
This connection must link the adju-
stment mechanism outlet located on the
side of the mechanism itself with the
outside.
This can be achieved with a flexible alu-
minium pipe and properly sealing the
points where air leakage could occur.
The Ø20 aluminium pipe can be posi-
tioned independently either to the
right or to the left of the adjustment
mechanism.
It is advisable to place a protection gril-
le on the outer part of the air inlet chan-
nel, nevertheless ensuring that this does
not reduce the cross-section.
The inflow of outside air must be at floor
level (it can not come from above).
.
When positioning the outdoor air
damper control cable (4c), make sure
that it does not come into contact with
the hot parts of the fireplace, as this
will damage the plastic sheath.
fig. E
fig. F
fig. G
Transporting the fireplace
In order to facilitate transportation, the
fireplace can be made lighter by remo-
ving the following:
- counter weights, cast iron bottom, cast
iron sides, cast iron hearth, the ash pan, the
ash grill made of cast iron, the outer shell.
Dismantling the door
Phase 1 (fig. H-I)
- lower the door to the fully closed
position
- move levers X and X1 to the closed
position.
Phase 2 (fig. L)
- open the door
- loosen safety grub screw Y
- reclose the door
- move levers X and X1 back to the
open position
Phase 3 (fig. L)
- lift the door up approximately 10 cm
in order to fully unscrew the Allen
screw (Z).
- lower the door until it is in the fully
closed position
- Take care that the door does not come
out of its housing.
- move levers X and X1 to the closed
position again, and then open the
door.
- pull (very carefully) the lower part of
the door towards you, in order to
remove it from its housing.
Cleaning the glass (fig. M)
- Note: before proceeding, move the
two levers, X and X1, to the closed
position (see fig. H - I).
- open the door and using the appro
priate tool (cold handle supplied)
release the latch plate on the jamb of
the short side of the door (rotate 90°).
- relcose after cleaning, fastening the
latch plate.
18
X
closed
open
fig. H
X1
open
fig. I
Y
Z
fig. L
fig. M
closed
Tabla de contenido
loading

Tabla de contenido