TECHNICAL DATA

R70 2AC
POWER SUPPLY
NUMBER OF ACTIVATED MOTORS
MAXIMUM POWER PER MOTOR
MAXIMUM POWER FOR FLASHING LIGHT
MAXIMUM POWER FOR OPEN GATE INDICATOR LIGHT
MAXIMUM POWER FOR ACCESSORIES OUTPUT
MAXIMUM POWER FOR ELECTRIC LOCK
MAXIMUM POWER FOR ACCESSORIES OUTPUT
WORKING TEMPERATURE
TORQUE ADJUSTMENT
OPERATING TIME
PAUSE TIME
DELAY TIME FOR 2nd MOTOR WHEN CLOSING
PEDESTRIAN GATE OPENING TIME
12 V
0 V
24 V
12 V
0 V
TRANSF.
4
TRIMMER
DIP ADJUSTMENT
RADIO BOARD
TEST FOTO
foto standard
foto test enabled
F2 1A
F4 1A
F3 1A
ADJUSTMENT OF THE TORQUE
NEUTRAL 230V
PHASE 230 V
R 70 2AC
230 Vac +/- 10% 50 Hz
2 asynchronous single-phase
400 W 230 Vac
40 W 230 Vac
100 W 230 Vac
2 W 24 Vac
25 W 12 Vac
300 mA 24 Vac
-10 + 55 °C
with autotransformer on 4 positions
adjustable from 2 to 60 seconds, extendable up to 120
adjustable from 0 to 90 seconds
adjustable from 0 to 20 seconds
adjustable from 2 to 60 seconds, extendable up to 120
37
36
35
34
M2
M1
F1
6,3 A
COMMON
STOP
PEDESTRIAN
STEP BY STEP
CLOSED
OPEN
COMMON
M2 LIMIT SWITCH
M2 LIMIT SWITCH
M1 LIMIT SWITCH
M1 LIMIT SWITCH
SAFETY EDGE
PHOTOCELL 2
PHOTOCELL 1
COMMON
24 Vac TST
24 Vac ACCESSORIES
COMMON
OPEN GATE INDICATOR LIGHT
COMMON
ELECTRIC LOCK
CLOSED MOTOR 2
COMMON MOTOR 2
OPEN MOTOR 2
CLOSED MOTOR 1
COMMON MOTOR 1
OPEN MOTOR 1
FLASHING LIGHT
COMMON FOR LIGHTS
COURTESY LIGHT
NEUTRAL 230 V
PHASE 230 V