Dip-Switches Settings - Aprimatic Flexi 300EL Manual De Instrucciones

Central de comando para 2 motores 24vdc
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4A - DIP-SWITCHES SETTINGS
A change of the DIP 1 "MODE" needs the repetition of the programming procedure.
!
DIP
DESCRIPTION
MODE
1
STEP
2
3
AUTO
4
PHO 2
5
LAMP
6
STRIKE
7
FAST
8
RADIO
4B - TRIMMER SETTINGS
A variation on the setting of "FOR" trimmer (power/speed) requires the repetition of the learning
!
procedure (point 2), because of the change of the manoeuvre time. The slowdowns are automatically set in
the last 15% of the travel.
Regulation from 50% to 100% of the power to the motors.
This parameter will also weigh on the manoeuvre speed.
Regulation of intervention time from 0.1 to 3 seconds.
The lower the trimmer is regulated, earlier the central will stop the
automation in case of impact of the wing against an obstacle.
Regulation of pause time at the end of the manoeuvre, before the
automatic reclosing from 0 to 90 seconds. The "AUTO" dip switch
Delay between the wings in closing (DELAY)
Regulation of the wings during the closing adjustable from 0 to
4 - CONTROL UNIT SETTINGS
DIP STATUS FUNCTIONING
Slow mode
ON
OFF
Fast mode
ON
Opening / Stop / Closing / Stop modality (step by step)
OFF
Opening / Pause / Closing (it accepts only opening commands)
ON
Yes automatic reclosing (set by "PAU" trimmer)
OFF
No automatic reclosing
ON
Stop and it keeps on opening after clearing in opening (PHO2 , working as photocell)
OFF
Stop and it recloses for 2 seconds in opening (PHO2, working as pneumatic edge)
Flashing light
ON
OFF
Steady light
Kick-back enabled
ON
OFF
Kick-back disabled
Yes rapid automatic reclosing
ON
OFF
No rapid automatic reclosing
ON
START radio channel programming procedure (see paragraph 3A)
OFF
Pedestrian opening radio channel programming procedure (see paragraph 3B)
Obstacle sensitivity (OBSTACLE):
Power/Speed (POWER):
Pause time (PAUSE):
must be ON.
15 seconds.
MAX
MAX
MAX
MAX