A
B
C
D
6
2. Installation
1.
Write the installation date on the unit with a
water-resistant pen. (Fig A)
2.
Remove the end cap of the lubricator. (Fig B)
3.
Turn the dial to activate the lubricator. (Fig C)
4.
Clean the area around the lubrication point.
5.
Remove the previous unit or old grease fitting.
A
6.
Attach the new unit hand tight. (Fig D)
7.
We recommend to check the general condition of the
bearing and the position of the lubricator piston every
normal manual lubrication interval.
When the unit is installed on a new application:
1.
Make sure that the grease in the SYSTEM 24 is
suitable.
2.
Fill the supply lines and the bearing with grease.
3.
Make sure the grease is compatible.
4.
Make sure the ambient temperature is within the
acceptable limits. If the ambient temperature is
constantly above +40 °C do not select a dispense rate
of more than 6 months for optimum performance.
5.
Make sure the unit supplies grease to the bearing,
or component to be lubricated.
6.
Make sure that there is no connection for a
grease gun on the same lubrication point.
7.
Install the unit no more than 300 mm (grease) or
1 500 mm (oil) from the bearing.
8.
Use only supply lines with an internal diameter of
6 mm.
9.
Protect the unit against impact or vibration.
Use the protection base LAPP 4 to shield the unit,
or install the unit remotely.
10. Protect the unit against heat and sudden temperature
changes.
SKF SYSTEM 24 - LAGD 60 / LAGD 125