Installation (continued)

PLACEMENT

Move the assembled unit to its final location. If required, level the unit by adjusting the four leveling legs. Ensure that no rocking is exhibited.

DRAINAGE

The tailpipe (not supplied) previously installed to the drain can now be connected to your household plumbing . In some cases, your household
plumbing will have to be modified to ensure proper drainage. If so, please consult a licensed plumber to complete
needed modifications.
SUPPLY LINES (NOT INCLUDED)
Connect the supply lines to your home's water supply as per manufacturer's instructions .
Open the hot and cold water supply valves and check to make sure they have
been installed to appropriate inlet ports . Check for leaks . Run hot and cold water
uninterrupted for about one minute to remove any residue from the lines .

Maintenance

CARTRIDGE REPLACEMENT

-
Turn off the water supply to the faucet .
-
Remove the setscrew cap . Loosen the setscrew with the hex
key provided and remove the handle .
-
Gently unscrew the decorative cap by hand . Use a wrench to
unscrew the retaining nut .
-
Pull the cartridge out of the faucet body and replace it with a
new ceramic cartridge . Ensure new cartridge is seated properly
with the locating pins in appropriate place .
-
Secure the cartridge in place using the retaining nut .
-
Gently tighten the retaining nut using a wrench .
Do not overtighten .
-
Reinstall the decorative cap . Slide the handle back onto the
lever arm and make sure it rotates freely . Secure the handle in
place using the setscrew and cover it with the setscrew cap .
-
Turn the water supply to the faucet back on .
-
Operate the faucet to make sure everything works correctly .
QL035
Cartridge
Faucet body
10
Retaining Nut
Decorative Cap
Handle
Setscrew
Setscrew Cap