Safety • Specifications; General Information - Flotec FPCC5030 Manual Del Usuario

Sistema de batería de respaldo
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Safety • Specifications

GENERAL INFORMATION

The Battery Backup Combo Kit is pre-plumbed up to
the hose and clamp assembly. The system includes the
primary sump pump (PSP), backup sump pump (BSP)
assembly, and vertical float switch. The unit is equipped
with two check valves - one for the primary pump and
one for the backup pump.
The battery backup pump is not a substitute for your
primary sump pump. It is designed to temporarily backup
your primary sump pump during a power outage or other
problem which prevents normal operation of the primary
pump. Do not use this system to pump flammable liquids
or chemicals. Pump clear sump water only with this
pump. For residential use only.
Keep the battery charger dry and protected from damage.
This system is designed to work with either a sealed
lead-acid AGM battery or a flooded lead-acid battery.
Use of a true Gel Cell (often confused for AGM) or a
standard automotive battery with this charger is not
recommended. An automotive battery may require
charging after only 1-2 hours of continuous use, and the
repeated charging cycles may cause early plate failure in
the battery.
Specifications
Maximum vertical pumping distance is 15 feet (4.6M) for
Model FPCC5030.
Power supply required
Primary Sump Pump ............................115V, 60 HZ.
Backup Sump Pump ......................... 12V DC Battery
Liquid Temp. Range .......................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ......... 15 Amps
Discharge:
Hose & Clamp Assembly ............1-1/4"Slip / 1-1/2"Slip
Minimum pit diameter ............................................... 14"
Minimum depth ........................................................ 10"
NOTICE Do not reduce size of discharge pipe or hose
below 1-1/4" diameter. If discharge is too small, pump
will overheat and fail prematurely.
NOTICE If a Carbon Monoxide (CO) sensor is installed,
it must be at least 15 feet away from battery charger
in order to avoid nuisance CO alarms. Please refer
to your CO detector's installation guidelines for more
information.
Performance - PSP
GPH (LPH) at total feet (m) of lift
5
Series
HP
(1.5m)
Capacity Gallons(L)/Hour
Primary
3660
1/2
(FPZS50V)
(13855)
Performance - BSP
GPH (LPH) at total feet (m) of lift
0
Series
(0)
(1.5m)
Capacity Gallons(L)/Hour
Backup
2700
2040
(PS17-2005)
(10221)
(7722)
Electrical & Switch Specifications
Motor
Full Load
Series
HP
Amps
FPZS50V
1/2
4.1
PS17-2005
-
-
Required Battery Capacity:
For best results, use the following AGM Storage Batteries:
Part
Amp-Hour
BAT40
40
BAT75
75
Unit equipped with dual battery capability
Maximum amp-hour: 120
38-120 Ampere-Hour Storage or Deep Cycle Battery
10
15
20
(3m)
(4.6m)
(6.1m)
3000
2160
960
(11356)
(8176)
(3634)
5
10
14
(3m)
(4.3m)
1260
360
(4770)
(1363)
Branch
Switch Setting in
Circuit
inches (cm)
Req.
(Amps)
On
7.5
19.1)
15
10.5
(26.7)
Gal/Charge
Approx Run
at 10'
4,800
5 Hours
11,500
11.5 Hours
3
MAX.
LIFTr
22 ft
(6.7m)
MAX.
LIFT
15
(4.6m)
Off
3
(7.6)
10.19
(25.9)
Time
Tabla de contenido

Solución de problemas

loading

Tabla de contenido