8. Instrument messages during operation
8. Instrument messages during operation
Display
Description
The scales are trying to effect a zero setting
2ERO
The alibi memory is selected, but on starting the scales, no alibi memory is connec-
AL.Err
ted or the data communication between the display and the keypad is faulty.
Er I.b.H A function is linked to input X (from 1 to 4) and is not
"
under
input5
Er.r.b.H In a switch point function, the relay X (from 1 to 4) has been set and is not "present".
See SETUP area under
Printing is in progress (serial connection PRN is busy) or the display unit is waiting to
busy
be able to send a print to the PC.
Printing attempt with an unstable weight.
unstAb
Printing attempt in over or underload condition, i.e. with a weight that is 9 scale divisi-
un.oUEr
ons greater than the nominal load or 100 scale divisions under the gross zero.
The net weight is less than the minimum load required for printing or totalling, or less
LoW
than the minimum weight for transferring a data string by pushbutton.
no.0 . .un5 Weight has not passed net 0 or was not unstable (depending on configuration).
On legally calibrated instruments, an attempt was made to print in the standard
ConU.
setting while the instrument was adjusting the weight unit.
In the input/output function (activated as
no
in
acquire the input weight.
In the input/output function (activated as
no out
acquire the output weight.
In the input/output function (activated as
no
1
made to acquire the input weight.
In the input/output function (activated as
no
2
made to acquire the output weight.
Unstable weight.
Er.Not
In counting mode, the reference determination was not or not properly performed, or
Error
a larger reference quantity is required. During the comparison procedure, the load
cell with which the comparison is performed does not correspond to the rated load or
values have not been entered or have been entered in the wrong order.
Is displayed when the execution of the comparison was not possible.
E9 . .Err
Is displayed when data has been stored in the permanent memory of the instrument
StorE
(switch points, tare, updated record, etc.)
Problem with the date/time cards. Setting of
Err.Clk
Date/Time not set. Setting of
SEt.Clk
Is displayed when attempting to perform the zero calibration without first confirming
PrEC.
the number of calibration points.
WIKA operating instructions SF
".
"
"
.
output
"
"
F.NodE
gas filling cart, model GFU08
6
"
"
present
. See SETUP area
"
"
), a second attempt was made to
in .out
"
"
), a second attempt was made to
in .out
"
"
"
"
or
), a second attempt was
G.t.
1St.2nd
"
"
"
"
or
), a second attempt was
G.t.
1St.2nd
"
"
"
>>
F.NodE
Clock
"
"
>>
in SETUP.
Clock
EN
"
in SETUP.
33