Routine Maintenance - CleanCraft HDR-H 108-20 Manual De Instrucciones

Hidrolavadoras de agua caliente
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
• Wind up the high pressure hose (35) with due care, making sure it is not bent. For products without a
hose reel, hang it up on its support (10).
• Wind up the power cord (6) and hang it up on its support (10).
• Store the high pressure cleaner in a clean, dry place. Make sure the power cord and the high
pressure hose are not damaged.
Follow the instructions for
MAINTENANCE
SCHEDULE
E v e r y t i me t he
• Check the power cord, the high pressure hose, the connectors, the cleaner gun and
cleaner is used
Once a Week
• Check the water inlet filter (18) and clean it if necessary.
Once a Month
• Clean the nozzle. To clean the nozzle, it is generally sufficient to insert the pin (31)
• Check the pump oil level.
Supplementary maintenance should only be carried out by a
table below (guideline only).
MAINTENANCE
SCHEDULE
Every 200 hours
Every 500 hours
24

ROUTINE MAINTENANCE

"STOPPING WORK"
the lance pipe.
Should any of these look damaged, do not use the cleaner for any reason and
contact a
QUALIFIED TECHNICIAN
Use a coin (Fig. 6) to turn the screw anticlockwise (37) and remove it; press the
lever (38) downwards and remove the cover (33) Unscrew the whole filter and
remove the filter cartridge.
Running water or compressed air is generally all that is needed to clean the filter
cartridge. In difficult cases, use a lime scale remover or replace the filter cartridge.
For tough cases, use a lime scale remover or replace it by contacting a
to buy the spare part.
TECHNICIAN
Replace the filter and put the cover back, following the above steps in reverse order.
supplied into the nozzle's hole. If no appreciable results are obtained, contact a
QUALIFIED TECHNICIAN
14 mm/0.55" spanner (not supplied).
Use the dipstick (51) (Fig. 6). If you need to top up the oil, contact a
TECHNICIAN.
SUPPLEMENTARY MAINTENANCE
• Check the pump's hydraulic circuit
(water).
• Check the pump is firmly secured
• Adjust the electrodes
• Change the pump oil
• Replace the electrodes
• Replace the fuel nozzle.
• Check the pump delivery/suction valves.
• Check the tightness of pump screws.
STORAGE
and those provided in the table below.
ACTION
.
to buy the spare part . The nozzle can be replaced using a
QUALIFIED TECHNICIAN
ACTION
, following the
• Clean the fuel nozzle.
• Check/replace the fuel filter.
• Check/replace the water filter
• Check the pump's adjustment valve
• Clean the boiler.
• Check the safety devices
QUALIFIED
QUALIFIED
Tabla de contenido
loading

Tabla de contenido