ROUTINE MAINTENANCE
CLEANING THE SENSOR FILTER
A
The sensor filter
can be accessed directly from the vacuum chamber; it is connected by means of a small tube
C
sensor
fixed on the rear of the machine.
1) Remove the tray dies and polythene insertion plates from the chamber.
2) Clean filter
A
with compressed air. If the residua are difficult to remove, unscrew the filter using a No. 13 hex wrench
(Fig. 1) and immerse it in a solution of water and vinegar, then dry with compressed air.
3) Remove the small tube
replace with a new tube, if necessary.
4) Refit the rear panel
D
A
46
B
from the sensor hose connector and the connector on the chamber to see if it is clean;
, by fixing the 10 screws using a No. 3 T male hex wrench, including the two screws
D
E
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
B
to
E
.
C
B
Fig. 1