13. TROUBLESHOOTING
PROBLEM
Machine not working.
The tray is not sealed pro-
perly.
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
POSSIBLE CAUSES
• Machine Off.
• No power supply.
• Machine damage.
• Sealing temperature incorrect.
• Tray smeared with oil or grease.
• Tray smeared with oil or grease because of
boiling of the liquid in the tray during the
vacuum creation phase.
• Red silicone rubber of the tray die
positioned correctly.
• Film roll positioned upside down with the
sealing side facing upwards.
• Film not compatible with tray.
• Sealing plate dirty or encrusted.
PF3
• Switch on the machine using the ON/OFF main switch.
• Insert the plug in a socket (check the voltage!).
• Check power cable to make sure it is intact.
• Check fuses PF3 and PF4 on the power board to make
sure they are intact and inserted correctly (VGP25N).
• Contact a Service centre.
• Adjust thermostat
to the material of the film and the tray.
• Clean/Change the tray.
• Reduce the liquid content in the tray.
• Insert the red silicone rubber in its seat.
B
not
• Turn the roll upside down.
• Use compatible film and trays.
• Clean by following the instructions in the "Mainte-
nance" chapter.
PF4
A
TROUBLESHOOTING
SOLUTION
A
to the correct value in relation
B
57
Tabla de contenido
loading

Este manual también es adecuado para:

Vgp25nVgp60n