6.1.1 General mounting instructions for solid shaft encoders
• Check the shafts for offset.
• Protect the tolerance-compensating element during mounting from excessive bending and from
damage.
• Align the coupling on the shafts, and tighten without preload.
The connection between encoder and drive shaft should be configured in such a way that any break-
age of the connection can be excluded.
6.1.2 General mounting instructions for hollow shaft encoders
• Slide the encoder on the shaft
• Screw the stator coupling/torque stop onto the flange of the drive, without preload.
• Tighten the clamping ring to the recommended torque, without applying any preload to the stator
coupling/torque stop.
• Minimum depth of insertion for hollow shaft encoders is: 34 mm [1.34].
6.1.3 Cable bending radius
Please respect the minimum permissible bending radii for the cables used.
The following values apply for encoders with cable outlet.
58xxFS
Fixed installation
R
75 [2.95]
min
70xxFS
Fixed installation
R
55 [2.17]
min
Dimensions in mm [inch]
16
Flexible use
110 [4.33]
Flexible use
100 [3.94]