Failure Display and Inspection
If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes. These are the most common
failures:
Error
Message
No cookware or cookware not suitable.
Water or cookware on the glass over the
ER03
control area.
Connection between the display board
and the left mainboard fails (the cooking
F1E
zone which indicator shows "E").
Coil temperature sensor failure. (in the
cooking zone which indicator shows
F3E
"E").
Mainboard temperature sensor failure.
(in the cooking zone which indicator
F4E
shows "E").
Temperature measured by the sensor of
E1E
the ceramic glass is too high.
Temperature sensor of the IGBT is too
E2 E
high.
Abnormal supply voltage (too high).
E3 E
E4 E
Abnormal supply voltage (too low).
Temperature
E5 E
cooking zone which indicator shows E").
Please do not disassemble the unit by yourself to avoid any dangers and damages to
the induction hob.
Choosing the right cookware (F5)
-
Preferably use cookware indicated as being suitable for induction cooking.
-
A magnet-attracting cookware may be suitable for induction cooking.
-
Stainless steel cookware with multi-layer or ferritic stainless-steel bases if the
base indicates: for induction cooking.
-
If cast iron cookware is used, it should preferably have an enamel bottom to avoid
scratching the ceramic hob surface.
-
The following types of cookware are not suitable: glass, ceramic, earthenware,
aluminium, copper or non-magnetic (austenitic) stainless steel.
-
Flat and thick-bottomed cookware.
-
A cookware with the same diameter as the cooking zone ensures the maximum
power is used.
-
A smaller cookware reduces the power but will not lead to energy loss. In any case,
Possible causes
sensor
failure
Replace the cookware.
Clean the control area.
1.Connection
plugged or defective.
2.Replace the mainboard.
Replace the coil sensor.
Replace the mainboard.
Please restart after the hob has been
cooled down.
Please restart after the hob has been
cooled down.
Please inspect whether power supply
is normal. Switch on after the power
supply is normal.
Please inspect whether power supply
is normal. Switch on after the power
supply is normal.
(in
the
Connection
plugged or the assembly is defective.
EN
What to do
cable
not
correctly
cable
not
correctly
Tabla de contenido