General; Technical Data - FEIG Electronic Sensors Instrucciones De Manejo

Detector digital de movimiento por radar
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2

General

The MWD BP Radar Motion Detector operates with a planar microwave antenna and is used on industrial
gates for entry and access recognition.
The device is intended for installation outdoors and is preset for typical gate applications.
Operation is via two buttons on the case or optionally using an infrared remote control. Thereby, the operator
prompting is done using a 7-Segment display.
The two output relays provided can be adjusted independently from each other in many ways.
The approach sensitivity and the direction logic can be adjusted for both channels of the motion detector.
The detector can also distinguish between people and vehicles and suppress cross-traffic.
3

Technical Data

Case dimensions (W x H x D):
Material
Case and retaining bracket
Cover
Weight with retaining bracket
Protection class
Supply voltage
Power consumption
Permissible operating temperature
Storage temperature
Relative humidity
Frequency
Transmission power
Output relay
max. switching voltage
max. switching current
min. switching load
contact type Relay 1
contact type Relay 2
Connection cable
Cable external diameter
Maximum mounting height
If the device becomes unusable, dispose it in accordance with the current statutory
regulations !
FEIG ELECTRONIC GmbH
Manual
135x65x130 mm
ASA
PC
160 g
IP65
12-27 V AC, 50 – 60 Hz
12-30 V DC, GND must be connected to PE.
SELV, limited capacity power source according to EN 60950-1
typical. 1.0W
max. 2.4W
-20 °C to +55 °C
-30 °C to +75 °C
< 95% non-condensing
24.125 GHz
typical. 40 mW EIRP
max. 100 mW EIRP
30 V AC/DC
1A for resitive load
1 mA / 5VDC
1 change over contact
1 normally open contact
A T T E N T IO N
The common of the relays is connected
directly to 24V with some Sensor versions, e.g. version –A.
IMPORTANT An external relay contacts protection circuit
must be provided for inductive load.
flexible, max. wire cross section 1.0 mm
5 – 7 mm
7m