Table 1
Before
Blinks
charging
(RED)
While
Lights
charging
(RED)
Charging
Blinks
(RED)
complete
Charging
Flickers
impossible
(RED)
Lights
Overheat
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the table below, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 2 Temperatures at which the battery can be
recharged
Charger
Rechargeable batteries
EB14B, EB1424,
EB1820L, EB1824L
EB1426H, EB1430H,
EB1433X, EB1826HL,
EB1830HL, EB1833X
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 3.
Table 3 Charging time (At 20°C)
Charger
UC14YFA
Battery
EB14B
Approx. 50 min.
EB1820L
EB1424
Approx. 60 min.
EB1824L
EB1426H Approx. 60 min.
EB1826HL
EB1430H Approx. 70 min.
EB1830HL
EB1433X Approx. 75 min.
EB1833X
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
Lights continuously
UC14YFA
UC18YRL
UC24YFA
UC18YFL
–5°C – 60°C
–5°C – 55°C
0°C – 45°C
–5°C – 50°C
UC18YRL
UC24YFA
UC18YFL
Approx. 50 min. Approx. 30 min.
Approx. 35 min.
Approx. 60 min.
Approx. 40 min.
Approx. 70 min. Approx. 45 min.
Approx. 75 min. Approx. 50 min.
NOTE:
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger firmly and pull out the battery.
NOTE:
After operation, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the first and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2 – 3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the battery
and recharge it after it has cooled for a while.
CAUTION:
If the battery is charged while it is heated because it
has been left for a long time in a location subject to
direct sunlight or because the batetery has just been
used, the pilot lamp of the charger lights up green. In
such a case, first let the battery cool, then start
charging.
English
Malfunction in the battery
or the charger
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)