14.6 Doses Adjustment Time Scheme
Each one of the 8 selections can be adjusted, modifying the following parameters:
Coffee Water Vol
BEFORE
SOLUBILE
Wate
Time 1 Water 1
Soluble Delay
14.7 Doses recommendations (examples):
On an attached document, different adjusting sets will be found depending on the country.
Note: Set the times as for the soluble ingredients to stop always around 1 second before the stop of
the pumping of water.
Set as well the mixer to work always around 2 seconds longer than the stop of the water and/or the
soluble ingredients. Not respecting this rules, will cause the mixer to clog.
14.8 Machine Parameters Menu
After the doses menu, we arrive to the Machine Parameters menu:
In this menu we will be able to adjust important parameters of the machine.
Pressing the "Enter" button, we get into the menu and the display shows the first parameter
available to be adjusted:
14.8.1
Language:
With buttons "+" and "-" we select the different languages; with "enter" we accept the selected
language, and proceed to the next adjustment.
Enter
LANGUAGE
ENGLISH
Canc
Enter
Brewing coffee
BEFORE
Pause Water 1 Time 2 Water1
Mixer Time
Soluble time
Soluble
MACHINE PARAM.
+
+
LENGUA
SPRACHE
ESPANOL
DEUTSCH
-
-
Brewing coffee
AFTER
Wate
Time 1 Water 2
+
+
LINGUA
LANGUE
ITALIANO
FRANCAIS
-
-
37
• Technical programming
Coffee Water Vol
AFTER SOLUBLE
Pause Water 2
Time 2 Water2
T
English