Storage/Winterization
● Remove the unit at temperatures below 32 degrees Fahrenheit. Thoroughly clean and check the unit for damage.
● Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!

Wearing parts

Filter pads and impeller vanes are wearing parts; for this reason they are excluded from our warranty
Disposal
Do not dispose of this unit with domestic waste! Disable the unit beforehand by cutting off the cables. Further
information about the recycling of this product can be obtained from your local municipal authority.

Troubleshooting

Issue
Unit does not run
Insufficient delivery rate
No aeration
Unit switches off after a
short running period
Cause
No mains voltage
Impeller blocked
Leaf basket / filter pad soiled
Injector blocked
The aerating hose between the floating body
and the injector is kinked or disconnected
Water temperature too high
Solution
Check mains voltage
Clean
Clean
Clean
Ensure secure fastening and avoid kinks
in the aerating hose
Note maximum water temperature of 95°F
(+ 35°C)