Dismantling the GES R2 floor socket

WARNING
38 | EN
12
Dismantling the GES R2 floor socket
Danger to life from electrical current!
Contact with electrical current can lead to an electric shock .
Fatal or series injuries are possible .
Electrical work may only be carried by specialist personnel with electrical
training!
When dismantling the GES R2 floor socket, the lid must first be
removed . Then, the entire installation socket can be removed from
the base opening . Further dismantling takes place outside the
base opening .
12 1

Required tools

Battery-operated screwdriver or
screwdriver
Knife
12 2

Dismantling the lid

1 . For metallic lids: Cut the sealing compound .
2 . Using a suitable tool, unlock the three locking hooks (e .g . flat
screwdriver, see Fig .
3 . Using a suitable tool, secure the locking hooks against relo-
cking .
4 . Remove the lid .
12 3

Dismantling cover plates

1 . Using a suitable tool, lever off the two locking hooks (e .g . flat
screwdriver, 7 mm) and release the cover plate (see Fig .
) .
2 . Remove the cover plates by bending a connected plug .
12 4

Dismantling the installation socket

1 . Turn out the three screws until the universal fastenings fall off
of the screws (see Fig .
2 . Pull the installation socket out of the floor opening .
,
1
) .